show system environment

モード: 非特権EXECモード
カテゴリー: 運用・管理 / システム


> show system environment


本体、拡張モジュール、電源ユニット/ファンモジュールの動作環境に関する情報を表示する。


使用例

awplus# show system environment
Active Controller 5:
Overall Status: Normal

Resource ID: 1 Name: PSU Bay A ()
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                           No        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                         No        -          -       Ok
4   PSU Power Input                          No        -          -       Ok

Resource ID: 2 Name: PSU Bay B ()
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                           No        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                         No        -          -       Ok
4   PSU Power Input                          No        -          -       Ok

Resource ID: 3 Name: PSU Bay C ()
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                           No        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                         No        -          -       Ok
4   PSU Power Input                          No        -          -       Ok

Resource ID: 4 Name: PSU Bay D (AT-SBxPWR-SYS/AC)
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                          Yes        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                        Yes        -          -       Ok
4   PSU Power Input                         Yes        -          -       Ok

Resource ID: 5 Name: Fan Tray Slot (AT-SBxFAN)
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                          Yes        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok

Resource ID: 6 Name: AT-SBx81CFC
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Voltage: 2.5V (Volts)                2.487      2.344      2.865      Ok
2   Voltage: Battery (Volts)             3.023      2.700      3.586      Ok
3   Voltage: 3.3V (Volts)                3.283      2.973      3.627      Ok
4   Voltage: 1.0V (Volts)                0.984      0.900      1.097      Ok
5   Temp: Internal (Degrees C)              41   78(Hyst)         80      Ok

Resource ID: 14 Name: AT-SBxFAN
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Fan: Fan 1 (Rpm)                      2967         82         -       Ok
2   Fan: Fan 2 (Rpm)                      2971         82         -       Ok
3   Fan: Fan 3 (Rpm)                      2950         82         -       Ok
4   Fan: Fan 4 (Rpm)                      2939         82         -       Ok
5   Temp: Temperature 1 (Degrees C)         31         -4         60      Ok
6   Temp: Temperature 2 (Degrees C)         31         -4         60      Ok
7   Temp: Temperature 3 (Degrees C)         30         -4         60      Ok


注意・補足事項

■ VCSマスターに対して本コマンドを実行した場合は、すべてのスタックメンバーに関する情報を表示する。

■ 電源ユニットスロット(PSU 1、PSU 2)は、電源ユニットが装着されていない場合でもStatus「Ok」と表示される。


関連コマンド

show system(非特権EXECモード)
show system pluggable(非特権EXECモード)