show system environment

モード: 非特権EXECモード
カテゴリー: 運用・管理 / システム


> show system environment


本体、拡張モジュール、電源ユニット/ファンモジュールの動作環境に関する情報を表示する。


使用例

awplus> show system environment
Environment Monitoring Status

Overall Status: Normal

Resource ID: 1  Name: PSU Bay A (AT-SBxPWRSYS2/AC)
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                          Yes        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                        Yes        -          -       Ok
4   PSU Power Input                         Yes        -          -       Ok

Resource ID: 2  Name: PSU Bay B ()
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Device Present                           No        -          -       Ok
2   Fan/Temperature Fault                    No        -          -       Ok
3   PSU Power Output                         No        -          -       Ok
4   PSU Power Input                          No        -          -       Ok

Resource ID: 3  Name: SwitchBlade x908 GEN2
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Voltage: 2.5V (Volts)                 2.500      2.344      2.865     Ok
2   Voltage: Battery (Volts)              3.164      2.700      3.586     Ok
3   Voltage: 3.3V (Volts)                 3.300      2.973      3.627     Ok
4   Voltage: 12V (Volts)                 12.125     10.813     13.188     Ok
5   Voltage: 1V (Volts)                   0.998      0.900      1.097     Ok
6   Temp: Internal (Degrees C)               36   70(Hyst)         75     Ok
7   Fan:  Fan Tray A 1 Int (Rpm)           4023       3000        -       Ok
8   Fan:  Fan Tray A 1 Ext (Rpm)           3511       3000        -       Ok
9   Temp: Fan Tray A 1 (Degrees C)           32         -5         70     Ok
10  Fan:  Fan Tray A 2 Int (Rpm)           4057       3000        -       Ok
11  Fan:  Fan Tray A 2 Ext (Rpm)           3683       3000        -       Ok
12  Temp: Fan Tray A 2 (Degrees C)           31         -5         70     Ok
13  Fan:  Fan Tray B 1 Int (Rpm)           3913       3000        -       Ok
14  Fan:  Fan Tray B 1 Ext (Rpm)           3468       3000        -       Ok
15  Temp: Fan Tray B 1 (Degrees C)           32         -5         70     Ok
16  Fan:  Fan Tray B 2 Int (Rpm)           4023       3000        -       Ok
17  Fan:  Fan Tray B 2 Ext (Rpm)           3583       3000        -       Ok
18  Temp: Fan Tray B 2 (Degrees C)           34         -5         70     Ok
19  Temp: Near Switch (Degrees C)            35   70(Hyst)         75     Ok
20  Temp: Front Left (Degrees C)             32   65(Hyst)         70     Ok
21  Temp: Front Mid (Degrees C)              30   65(Hyst)         70     Ok
22  Temp: Front Right (Degrees C)            33   65(Hyst)         70     Ok
23  Temp: Console (Degrees C)                31   55(Hyst)         60     Ok

Resource ID: 4  Name: AT-XEM2-12XS  Bay: 1
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Temp: XEM Front (Degrees C)              28   60(Hyst)         65     Ok
2   Temp: XEM Rear (Degrees C)               35   65(Hyst)         70     Ok

Resource ID: 5  Name: AT-XEM2-12XS  Bay: 2
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Temp: XEM Front (Degrees C)              29   60(Hyst)         65     Ok
2   Temp: XEM Rear (Degrees C)               37   65(Hyst)         70     Ok

Resource ID: 6  Name: AT-XEM2-12XT  Bay: 3
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Temp: XEM Front (Degrees C)              28   55(Hyst)         60     Ok
2   Temp: XEM Rear (Degrees C)               33   70(Hyst)         75     Ok

Resource ID: 7  Name: AT-XEM2-12XS  Bay: 7
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Temp: XEM Front (Degrees C)              28   60(Hyst)         65     Ok
2   Temp: XEM Rear (Degrees C)               36   65(Hyst)         70     Ok

Resource ID: 8  Name: AT-XEM2-12XS  Bay: 8
ID  Sensor (Units)                      Reading  Low Limit High Limit Status
1   Temp: XEM Front (Degrees C)              29   60(Hyst)         65     Ok
2   Temp: XEM Rear (Degrees C)               37   65(Hyst)         70     Ok
NGT-bo15-x908G2#


注意・補足事項

■ VCSマスターに対して本コマンドを実行した場合は、すべてのスタックメンバーに関する情報を表示する。


関連コマンド

show system(非特権EXECモード)
show system pluggable(非特権EXECモード)



(C) 2018 - 2019 アライドテレシスホールディングス株式会社

PN: 613-002656 Rev.C