[index] CentreCOM x950シリーズ コマンドリファレンス 5.4.9
モード: 非特権EXECモード
カテゴリー: 運用・管理 / システム
> show system environment
本体、拡張モジュール、電源ユニット/ファンモジュールの動作環境に関する情報を表示する。
awplus> show system environment ↓ Environment Monitoring Status Overall Status: Normal Resource ID: 1 Name: PSU Bay A (AT-SBxPWRSYS2/AC) ID Sensor (Units) Reading Low Limit High Limit Status 1 Device Present Yes - - Ok 2 Fan/Temperature Fault No - - Ok 3 PSU Power Output Yes - - Ok 4 PSU Power Input Yes - - Ok Resource ID: 2 Name: PSU Bay B () ID Sensor (Units) Reading Low Limit High Limit Status 1 Device Present No - - Ok 2 Fan/Temperature Fault No - - Ok 3 PSU Power Output No - - Ok 4 PSU Power Input No - - Ok Resource ID: 3 Name: SwitchBlade x908 GEN2 ID Sensor (Units) Reading Low Limit High Limit Status 1 Voltage: 2.5V (Volts) 2.500 2.344 2.865 Ok 2 Voltage: Battery (Volts) 3.164 2.700 3.586 Ok 3 Voltage: 3.3V (Volts) 3.300 2.973 3.627 Ok 4 Voltage: 12V (Volts) 12.125 10.813 13.188 Ok 5 Voltage: 1V (Volts) 0.998 0.900 1.097 Ok 6 Temp: Internal (Degrees C) 36 70(Hyst) 75 Ok 7 Fan: Fan Tray A 1 Int (Rpm) 4023 3000 - Ok 8 Fan: Fan Tray A 1 Ext (Rpm) 3511 3000 - Ok 9 Temp: Fan Tray A 1 (Degrees C) 32 -5 70 Ok 10 Fan: Fan Tray A 2 Int (Rpm) 4057 3000 - Ok 11 Fan: Fan Tray A 2 Ext (Rpm) 3683 3000 - Ok 12 Temp: Fan Tray A 2 (Degrees C) 31 -5 70 Ok 13 Fan: Fan Tray B 1 Int (Rpm) 3913 3000 - Ok 14 Fan: Fan Tray B 1 Ext (Rpm) 3468 3000 - Ok 15 Temp: Fan Tray B 1 (Degrees C) 32 -5 70 Ok 16 Fan: Fan Tray B 2 Int (Rpm) 4023 3000 - Ok 17 Fan: Fan Tray B 2 Ext (Rpm) 3583 3000 - Ok 18 Temp: Fan Tray B 2 (Degrees C) 34 -5 70 Ok 19 Temp: Near Switch (Degrees C) 35 70(Hyst) 75 Ok 20 Temp: Front Left (Degrees C) 32 65(Hyst) 70 Ok 21 Temp: Front Mid (Degrees C) 30 65(Hyst) 70 Ok 22 Temp: Front Right (Degrees C) 33 65(Hyst) 70 Ok 23 Temp: Console (Degrees C) 31 55(Hyst) 60 Ok Resource ID: 4 Name: AT-XEM2-12XS Bay: 1 ID Sensor (Units) Reading Low Limit High Limit Status 1 Temp: XEM Front (Degrees C) 28 60(Hyst) 65 Ok 2 Temp: XEM Rear (Degrees C) 35 65(Hyst) 70 Ok Resource ID: 5 Name: AT-XEM2-12XS Bay: 2 ID Sensor (Units) Reading Low Limit High Limit Status 1 Temp: XEM Front (Degrees C) 29 60(Hyst) 65 Ok 2 Temp: XEM Rear (Degrees C) 37 65(Hyst) 70 Ok Resource ID: 6 Name: AT-XEM2-12XT Bay: 3 ID Sensor (Units) Reading Low Limit High Limit Status 1 Temp: XEM Front (Degrees C) 28 55(Hyst) 60 Ok 2 Temp: XEM Rear (Degrees C) 33 70(Hyst) 75 Ok Resource ID: 7 Name: AT-XEM2-12XS Bay: 7 ID Sensor (Units) Reading Low Limit High Limit Status 1 Temp: XEM Front (Degrees C) 28 60(Hyst) 65 Ok 2 Temp: XEM Rear (Degrees C) 36 65(Hyst) 70 Ok Resource ID: 8 Name: AT-XEM2-12XS Bay: 8 ID Sensor (Units) Reading Low Limit High Limit Status 1 Temp: XEM Front (Degrees C) 29 60(Hyst) 65 Ok 2 Temp: XEM Rear (Degrees C) 37 65(Hyst) 70 Ok NGT-bo15-x908G2#
■ VCSマスターに対して本コマンドを実行した場合は、すべてのスタックメンバーに関する情報を表示する。
show system(非特権EXECモード)
show system pluggable(非特権EXECモード)
(C) 2018 - 2019 アライドテレシスホールディングス株式会社
PN: 613-002656 Rev.E