[index] AT-ARX200S-GTX コマンドリファレンス 5.5.4
モード: 非特権EXECモード
カテゴリー: 運用・管理 / システム
> show system environment
本体の動作環境に関する情報を表示する。
awplus> show system environment ↓ Environment Monitoring Status Overall Status: Normal Resource ID: 1 Name: ARX200S ID Sensor (Units) Reading Low Limit High Limit Status 1 Fan: PSU Fan (Rpm) 5696 2000 - Ok 2 Temp: Temp D1 (Degrees C) 25 59(Hyst) 64 Ok 3 Temp: Temp D2 (Degrees C) 24 57(Hyst) 62 Ok 4 Temp: Temp NCT (Degrees C) 26 61(Hyst) 66 Ok 5 Voltage: 12V (Volts) 12.011 10.800 13.199 Ok 6 Voltage: 3.3V (Volts) 3.333 2.970 3.630 Ok 7 Voltage: 1.2V (Volts) 1.209 1.080 1.320 Ok 8 Voltage: 0.85V (Volts) 0.855 0.765 0.935 Ok 9 Voltage: 1.05V (Volts) 1.051 0.945 1.155 Ok 10 Voltage: 1.8V (Volts) 1.820 1.619 1.980 Ok 11 Voltage: 1.5V (Volts) 1.512 1.349 1.650 Ok 12 Voltage: 1.2V (Volts) 1.211 1.080 1.320 Ok 13 Voltage: 0.7V (Volts) 0.695 0.629 0.770 Ok 14 Temp: SoC AP IC (Degrees C) 55 105(Hyst) 110 Ok 15 Temp: SoC AP CPU0 (Degrees C) 55 105(Hyst) 110 Ok 16 Temp: SoC AP CPU1 (Degrees C) 55 105(Hyst) 110 Ok 17 Temp: SoC AP CPU2 (Degrees C) 55 105(Hyst) 110 Ok 18 Temp: SoC AP CPU3 (Degrees C) 55 105(Hyst) 110 Ok 19 Temp: SoC CP0 IC (Degrees C) 40 105(Hyst) 110 Ok 20 Temp: SoC CP1 IC (Degrees C) 44 105(Hyst) 110 Ok
show system(非特権EXECモード)
(C) 2024 アライドテレシスホールディングス株式会社
PN: 613-003319 Rev.A