awplus> show system environment ↓ Environment Monitoring Status Stack member 1: Overall Status: Normal Resource ID: 100 Name: AT-x330-52GTX ID Sensor (Units) Reading Low Limit High Limit Status 1 Fan: Fan (Rpm) 3778 2025 - Ok 2 Voltage: 1.5V (Volts) 1.488 1.339 1.651 Ok 3 Voltage: 1.0V (Volts) 0.979 0.891 1.090 Ok 4 Voltage: 3.3V (Volts) 3.286 2.960 3.631 Ok 5 Voltage: 0.8V (Volts) 0.805 0.707 0.864 Ok 6 Voltage: 12V (Volts) 11.843 10.767 13.166 Ok 7 Temp: Switch (Degrees C) 45 -10 76 Ok 8 Temp: Internal (Degrees C) 45 -10 75 Ok 9 Temp: Console (Degrees C) 36 -10 66 Ok Stack member 2: Overall Status: Normal Resource ID: 100 Name: AT-x330-20GTX ID Sensor (Units) Reading Low Limit High Limit Status 1 Voltage: 1.5V (Volts) 1.491 1.339 1.651 Ok 2 Voltage: 1.0V (Volts) 1.005 0.891 1.090 Ok 3 Voltage: 3.3V (Volts) 3.312 2.960 3.631 Ok 4 Voltage: 0.8V (Volts) 0.805 0.707 0.864 Ok 5 Voltage: 12V (Volts) 11.859 10.767 13.166 Ok 6 Temp: Switch (Degrees C) 42 -10 73 Ok 7 Temp: Internal (Degrees C) 42 -10 71 Ok 8 Temp: Console (Degrees C) 40 -10 69 Ok
Note上記表示は一例です。表示される内容は製品、バージョン、機器構成などによって異なります。
■ VCSマスターに対して本コマンドを実行した場合は、すべてのスタックメンバーに関する情報を表示する。
show system(非特権EXECモード)
show system pluggable(非特権EXECモード)
(C) 2021 - 2025 アライドテレシスホールディングス株式会社
PN: 613-003033 Rev.S