show system environment
- モード
- 非特権EXECモード
- カテゴリー
- 運用・管理 / システム
構文
> show system environment
コマンド説明
製品の動作環境に関する情報(環境センサーの情報)を表示する。表示される内容は製品、バージョン、機器構成などによって異なる。
使用例
awplus> show system environment
Environment Monitoring Status
Card 1.1:
Overall Status: Normal
Resource ID: 100 Name: AT-SBx81XLEM
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 1.8V (Volts) 1.784 1.615 1.979 Ok
2 Voltage: 1.5V (Volts) 1.491 1.350 1.645 Ok
3 Voltage: 3.3V (Volts) 3.283 2.973 3.627 Ok
4 Voltage: 3.3V (Volts) 3.307 2.969 3.620 Ok
5 Voltage: 12.0V (Volts) 12.250 10.813 13.188 Ok
6 Voltage: 1.0V (Volts) 1.027 0.900 1.097 Ok
7 Temp: Middle (Degrees C) 54 70(Hyst) 75 Ok
8 Temp: Front (Degrees C) 40 60(Hyst) 65 Ok
Card 1.3:
Overall Status: Normal
Resource ID: 100 Name: AT-SBx81XLEM
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 1.8V (Volts) 1.797 1.615 1.979 Ok
2 Voltage: 1.5V (Volts) 1.491 1.350 1.645 Ok
3 Voltage: 3.3V (Volts) 3.283 2.973 3.627 Ok
4 Voltage: 3.3V (Volts) 3.307 2.969 3.620 Ok
5 Voltage: 12.0V (Volts) 12.250 10.813 13.188 Ok
6 Voltage: 1.0V (Volts) 1.027 0.900 1.097 Ok
7 Temp: Middle (Degrees C) 54 70(Hyst) 75 Ok
8 Temp: Front (Degrees C) 41 60(Hyst) 65 Ok
Card 1.5:
Overall Status: Normal
Resource ID: 13 Name: PSU Bay A ()
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present No - - Ok
2 Fault No - - Ok
3 PSU Power Output No - - Ok
4 PSU Power Input No - - Ok
Resource ID: 14 Name: PSU Bay B ()
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present No - - Ok
2 Fault No - - Ok
3 PSU Power Output No - - Ok
4 PSU Power Input No - - Ok
Resource ID: 15 Name: PSU Bay C (AT-SBxPWRSYS2/AC)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
2 Fault No - - Ok
3 PSU Power Output Yes - - Ok
4 PSU Power Input Yes - - Ok
Resource ID: 16 Name: PSU Bay D ()
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present No - - Ok
2 Fault No - - Ok
3 PSU Power Output No - - Ok
4 PSU Power Input No - - Ok
Resource ID: 17 Name: Fan Tray Slot (AT-SBxFAN12)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
2 Fault No - - Ok
Resource ID: 100 Name: AT-SBx81CFC960 v2
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 2.5V (Volts) 2.461 2.344 2.865 Ok
2 Voltage: Battery (Volts) 3.094 2.700 3.586 Ok
3 Voltage: 3.3V (Volts) 3.300 2.973 3.627 Ok
4 Voltage: 1.0V (Volts) 0.998 0.900 1.097 Ok
5 Temp: Internal (Degrees C) 53 65(Hyst) 70 Ok
Resource ID: 117 Name: AT-SBxFAN12
ID Sensor (Units) Reading Low Limit High Limit Status
1 Fan: Fan 1 (Rpm) 2955 82 - Ok
2 Fan: Fan 2 (Rpm) 2968 82 - Ok
3 Fan: Fan 3 (Rpm) 2944 82 - Ok
4 Fan: Fan 4 (Rpm) 2970 82 - Ok
5 Temp: Temperature 1 (Degrees C) 32 -5 60 Ok
6 Temp: Temperature 2 (Degrees C) 32 -5 60 Ok
7 Temp: Temperature 3 (Degrees C) 30 -5 60 Ok
Card 1.6:
Overall Status: Normal
Resource ID: 100 Name: AT-SBx81CFC960
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 2.5V (Volts) 2.487 2.344 2.865 Ok
2 Voltage: Battery (Volts) 3.080 2.700 3.586 Ok
3 Voltage: 3.3V (Volts) 3.283 2.973 3.627 Ok
4 Voltage: 1.0V (Volts) 0.998 0.900 1.097 Ok
5 Temp: Internal (Degrees C) 44 65(Hyst) 70 Ok
...
注意・補足事項
VCSマスターに対して本コマンドを実行した場合は、すべてのスタックメンバーに関する情報を表示する。電源ユニットスロット(PSU 1、PSU 2)は、電源ユニットが装着されていない場合でもStatus「Ok」と表示される。