show system environment
- モード
- 非特権EXECモード
- カテゴリー
- 運用・管理 / システム
構文
> show system environment
コマンド説明
製品の動作環境に関する情報(環境センサーの情報)を表示する。表示される内容は製品、バージョン、機器構成などによって異なる。
使用例
awplus> show system environment
Environment Monitoring Status
Stack member 1:
Overall Status: Normal
Resource ID: 9 Name: PSU Bay A ()
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present No - - Ok
2 Fault No - - Ok
3 PSU Power Output No - - Ok
4 PSU Power Input No - - Ok
Resource ID: 10 Name: PSU Bay B (AT-SBxPWRSYS2/AC)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
2 Fault No - - Ok
3 PSU Power Output Yes - - Ok
4 PSU Power Input Yes - - Ok
Resource ID: 11 Name: Fan Tray A (AT-FAN08)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
Resource ID: 12 Name: Fan Tray B (AT-FAN08)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
Resource ID: 100 Name: AT-SBx908 GEN2
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 2.5V (Volts) 2.487 2.344 2.865 Ok
2 Voltage: Battery (Volts) 3.150 2.700 3.586 Ok
3 Voltage: 3.3V (Volts) 3.300 2.973 3.627 Ok
4 Voltage: 12.0V (Volts) 12.125 10.813 13.188 Ok
5 Voltage: 1.0V (Volts) 0.998 0.900 1.097 Ok
6 Temp: Internal (Degrees C) 34 70(Hyst) 75 Ok
7 Temp: Fan Tray A 1 (Degrees C) 31 -5 70 Ok
8 Temp: Fan Tray A 2 (Degrees C) 29 -5 70 Ok
9 Temp: Fan Tray B 1 (Degrees C) 30 -5 70 Ok
10 Temp: Fan Tray B 2 (Degrees C) 31 -5 70 Ok
11 Temp: Near Switch (Degrees C) 34 70(Hyst) 75 Ok
12 Temp: Front Left (Degrees C) 30 65(Hyst) 70 Ok
13 Temp: Front Mid (Degrees C) 29 65(Hyst) 70 Ok
14 Temp: Front Right (Degrees C) 30 65(Hyst) 70 Ok
15 Temp: Console (Degrees C) 32 55(Hyst) 60 Ok
Resource ID: 101 Name: AT-XEM2-12XT Bay: 1
ID Sensor (Units) Reading Low Limit High Limit Status
1 Temp: XEM Front (Degrees C) 29 55(Hyst) 60 Ok
2 Temp: XEM Rear (Degrees C) 37 70(Hyst) 75 Ok
Resource ID: 111 Name: AT-FAN08
ID Sensor (Units) Reading Low Limit High Limit Status
1 Fan: Fan Tray A 1 Int (Rpm) 4072 3000 - Ok
2 Fan: Fan Tray A 1 Ext (Rpm) 3651 3000 - Ok
3 Fan: Fan Tray A 2 Int (Rpm) 3997 3000 - Ok
4 Fan: Fan Tray A 2 Ext (Rpm) 3624 3000 - Ok
Resource ID: 112 Name: AT-FAN08
ID Sensor (Units) Reading Low Limit High Limit Status
1 Fan: Fan Tray B 1 Int (Rpm) 4215 3000 - Ok
2 Fan: Fan Tray B 1 Ext (Rpm) 3846 3000 - Ok
3 Fan: Fan Tray B 2 Int (Rpm) 4238 3000 - Ok
4 Fan: Fan Tray B 2 Ext (Rpm) 3629 3000 - Ok
...