show system environment
- モード
- 非特権EXECモード
- カテゴリー
- 運用・管理 / システム
構文
> show system environment
コマンド説明
製品の動作環境に関する情報(環境センサーの情報)を表示する。表示される内容は製品、バージョン、機器構成などによって異なる。
使用例
awplus> show system environment
Environment Monitoring Status
Overall Status: Normal
System Airflow: Front to back
Resource ID: 2 Name: PSU Bay A (AT-PWR600)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
2 Fault No - - Ok
3 PSU Power Output Yes - - Ok
4 PSU Power Input Yes - - Ok
Resource ID: 3 Name: PSU Bay B ()
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present No - - Ok
2 Fault No - - Ok
3 PSU Power Output No - - Ok
4 PSU Power Input No - - Ok
Resource ID: 4 Name: Fan Bay A (AT-FAN05)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
Resource ID: 5 Name: Fan Bay B (AT-FAN05)
ID Sensor (Units) Reading Low Limit High Limit Status
1 Device Present Yes - - Ok
Resource ID: 100 Name: AT-x950-28XSQ
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: 2.5V (Volts) 2.487 2.344 2.865 Ok
2 Voltage: Battery (Volts) 3.136 2.700 3.586 Ok
3 Voltage: 3.3V (Volts) 3.317 2.973 3.627 Ok
4 Voltage: 12.0V (Volts) 12.000 10.813 13.188 Ok
5 Voltage: 1.0V CPU (Volts) 0.998 0.900 1.097 Ok
6 Temp: Internal (Degrees C) 36 70(Hyst) 75 Ok
7 Temp: Fan Tray A (Degrees C) 40 -5 70 Ok
8 Voltage: 1V Switch (Volts) 1.034 0.950 1.050 Ok
9 Temp: Fan Tray B (Degrees C) 39 -5 70 Ok
10 Temp: Switch Front (Degrees C) 37 65(Hyst) 70 Ok
11 Temp: Switch Rear (Degrees C) 45 75(Hyst) 80 Ok
12 Temp: PSU Bays (Degrees C) 37 70(Hyst) 75 Ok
13 Temp: Console (Degrees C) 33 70(Hyst) 75 Ok
Resource ID: 101 Name: AT-XEM2-4QS Bay: 1
ID Sensor (Units) Reading Low Limit High Limit Status
1 Temp: XEM Front (Degrees C) 29 55(Hyst) 60 Ok
2 Temp: XEM Rear (Degrees C) 33 60(Hyst) 65 Ok
Resource ID: 102 Name: AT-PWR600
ID Sensor (Units) Reading Low Limit High Limit Status
1 Voltage: PSU A Vin (Volts) 100.500 90.000 264.000 Ok
2 Voltage: PSU A Vout (Volts) 12.023 11.000 13.000 Ok
3 Current: PSU A Iin (Amps) 0.968 - 8.703 Ok
4 Current: PSU A Iout (Amps) 6.562 - 60.000 Ok
5 Power: PSU A Pin (Watts) 88.000 - 750.000 Ok
6 Power: PSU A Pout (Watts) 78.000 - 620.000 Ok
7 Fan: PSU A (Rpm) 13856 4000 - Ok
8 Temp: PSU A Intake (Degrees C) 38 -5 100 Ok
9 Temp: PSU A Exhaust (Degrees C) 45 -5 100 Ok
Resource ID: 104 Name: AT-FAN05
ID Sensor (Units) Reading Low Limit High Limit Status
1 Fan: Fan Tray A Left (Rpm) 7142 4000 - Ok
2 Fan: Fan Tray A Middle (Rpm) 7114 4000 - Ok
3 Fan: Fan Tray A Right (Rpm) 6601 4000 - Ok
Resource ID: 105 Name: AT-FAN05
ID Sensor (Units) Reading Low Limit High Limit Status
1 Fan: Fan Tray B Left (Rpm) 7346 4000 - Ok
2 Fan: Fan Tray B Middle (Rpm) 7258 4000 - Ok
3 Fan: Fan Tray B Right (Rpm) 7086 4000 - Ok