-- Copyright 2002-2009 by Allied Telesis, Inc. -- -- Name: AtiStackSwitch-MIB -- -- Version: 2.55 -- -- Products using this MIB: -- AT8324 -- AT8316F-MT -- AT8316F-VF -- AT8316F-SC -- AT8524M -- AT8550GB -- AT8516F -- AT9424T-SP -- AT9424T-GB -- -- History: -- Shyam Sethuram (ATI) 09/23/02 : Created the MIB -- -- Kishore Sorathia (ATI) 09/25/03 : Generalized to support AT-85XX -- Devices -- -- Enhanced Mirroring to support ingress/egress mirroring -- -- Kishore Sorathia (ATI) 09/30/03 : Added DOS (Denial Of Service) and -- QoS configuration. -- -- Kishore Sorathia (ATI) 10/24/03 : Modified atiStackSwitch.mib to add -- PortAdminState and PortStpState variables in Port table. The PortState -- (which was used to show both Port Admin state and RSTP State) variable -- is now obsolete and is kept for backward compatibilty. -- -- Kishore Sorathia (ATI) 02/06/04 : Modified to add product types for -- 9400 series products. -- -- Kishore Sorathia (ATI) 02/24/04 : Modified to add notes inside object -- descriptions to let user know which objects are not applicable for a -- particular product. -- Kishore Sorathia (ATI) 04/01/04 : Added Traps for STP port and trunk -- state change events. -- Tushar J. Patel (ATI) 05/06/2004: Updated the Port Mirroring State to -- disabled and l2-enabled. -- Tushar J. Patel (ATI) 06/10/2004: File revision 2.6 as per ATKK. -- Added Some information of Mirroring Compatibility fields -- Tushar J. Patel (ATI) 06/14/2004: Added AT-9424-GB switch oid -- Tushar J. Patel (ATI) 06/14/2004: Increased the QoS Egress to 8 levels -- for ATS63 -- Tushar J. Patel (ATI) 08/16/2004: (2.10)Deprecated some MIB defs, -- changed HOL to a Integer32 and some clean-up. Please read this file -- for details. -- Tushar J. Patel (ATI) a) 10/18/2004: (2.11)Added support for PortList -- to Static MAC Addresses, hence supporting Static Multicast support and -- added display of PortList for VLAN MacAddr Table -- b) Added support for at9408LC/SP and at8524-POE -- Tushar J. Patel. (ATI) a) 10/22/2004: Added support for RPSChnagedTrap -- b) " : Added support for MIB definitions for RPS -- Present and RPS State in ProductInfo -- Tushar J. Patel. (ATI) a) 11/02/2004: Added DC State in RPSTrap -- b) " : Added DC State in System ProductInfo -- Tushar J. Patel. (ATI) a) 11/10/2004: Added Counter64 support. Note: These -- counters will only work with SNMPv2. Users: Please make sure that the -- messaging is chnaged to SNMPv2 instead of v1. In addition, the 32 bit -- counters are no longer suitable for the new Gigabit support, hence, this -- mandatory change. If the 32 bit stats are required, please get them -- from the traditional IfEntry table (not ifXEntry table.) All previous -- Counter32 Private MIB statistics are now changed to Counter64 statistics. -- Tushar J. Patel (ATI) a) 11/24/2004: Added the IntrusionAttack table -- b) Updated the Intrusion Detection trap to provide -- Intruding MAC and Vlan. -- c) Version 2.12 of this file. -- Tushar J. Patel / Nelson Ho (ATI) -- a) 04/06/2005: Added support for the new UplinkInfo -- table as SysGroup 4. This table support switches -- with 94xx style of more than 2 uplinks -- (e.g. 9408LC/SP). This is released as version -- 2.13 of this MIB file. -- ****Note****: -- Please be aware of the limitation of the -- ProductInfo Table where upto 2 uplinks are -- supported. Though this support may continue; -- it is preferred that the new UplinkInfo table -- should be used in ATI release ATS63 1.1.1 and -- later. -- -- Nelson Ho (ATI) a) 04/20/2005 : Adding new product type for -- AT9424Ti/SP to AtiProductType textual convention (at9424Ti-SP(14)) -- b) Adding OID tree for at-9424Ti-SP as swHub 118. -- -- a) 04/28/05 : Add atiStkSwSysSystemTimeConfig Group -- for system time and SNTP support. -- -- a) 05/13/05 : Add atiStkSwSysInfoGroup for -- supporting the system information include system temperature, fan -- information and system voltage information. -- -- Nelson Ho (ATI) 09/13/05 : Obsolete the atiStkSwSysTrapRecv -- MIBs since the information from SNMPv3 Target Address Table. -- -- Nelson Ho (ATI) 09/14/05 : Add Object OID to support -- 9448Ts-XP platform. -- -- Nelson Ho (ATI) 09/23/05 : Add atiStkSwVlanActualUntaggedPortListModule1 object -- -- Nelson Ho (ATI) 10/19/05 : Add -- atiStkSwPortDOSAttackMirrorPortStatus mib Obsolete -- atiStkSwPortDOSAttackMirrorPort -- -- Nelson Ho (ATI) 11/18/05 : Add mstp enum to -- atiStkSwSysSpanningTreeVersion mib object -- -- Nelson Ho (ATI) 12/14/05 : Redefined the atiStkSwMib and ATI -- OID tree section -- -- Nelson Ho (ATI) 12/22/05 : Add atiStkSwGVRPConfig group & -- atiStkSwGVRPPortConfigTable -- -- Nelson Ho (ATI) 01/05/06 : Add atiStkSwQosFlowGrpTable -- -- Nelson Ho (ATI) 01/09/06 : Add atiStkSwQosTrafficClassTable -- -- Nelson Ho (ATI) 01/12/06 : Add atiStkSwQosPolicyTable -- -- Nelson Ho (ATI) 01/17/06 : Add atiStkSwGVRPCountersTable -- -- Nelson Ho (ATI) 01/18/06 : Add OID for new platform AT9448Ts, -- AT9448T-SP, AT9424Ts/XP -- -- Nelson Ho (ATI) 01/26/06 : Add new MIB atiStkSwSysAction -- -- Praveen Donthi (ATI) 03/07/06 : Added support for -- atiStkSwMgmtDisabledTrap -- -- Nelson Ho (ATI) 04/05/06 : Added comment for supporting -- AT-8588-SC platform. -- -- Nelson Ho (ATI) 04/11/06 : Add new MIB table -- atiStkSwQoSGroupPortCoSPriorityTable -- -- Nelson Ho (ATI) 04/18/06 : Add new MIB table -- atiStkSwStaticTrunkTable and atiStkSwTrunkGroup (atiStkSwMib 8) -- -- Nelson Ho (ATI) 04/24/06 : Add new MIB table -- atiStkSwACLConfigTable and new branch for atiStkSwACLGroup (atiStkSwMib 9) -- -- Nelson Ho (ATI) 04/27/06 : Add new MIB table -- atiStkSwSysMgmtACLConfigTable and new branch for atiStkSwSysMgmtACLGroup -- (atiStkSwSysGroup 7) -- -- Minal Agarwal (ATI) 06/26/06 : Add new MIB object -- atiStkSwSysTemperatureLimitValue and trap atiStkSwTemperatureLimitTrap -- -- Nelson Ho (ATI) v 2.33 08/12/06 : Remove MIB object -- atiStkSwSysTemperatureLimitValue from system Group Introduce -- atiStkSwSysTemperatureLimitValue under atiStkSwSysProductInfoTable -- -- Nelson Ho (ATI) v 2.34 08/25/06 : change the type of -- atiStkSwFanInfoState from integer to DisplayString (It is OK to change the -- type because the MIB has not official release to customer). -- -- Nelson Ho (ATI) v 2.35 09/08/06 : Introduce two new traps : -- atiStkSwFanOkTrap, atiStkSwTemperatureNormalTrap -- -- Nelson Ho (ATI) v 2.36 09/28/06 : Obsolete -- atiStkSwTemperatureAbnormalTrap. -- -- Junichi Katagiri (ATKK)v 2.37 12/18/07 : Add new MIB table -- atiStkSwPortStormDetectCurrentTable, and new traps for Storm Detection. -- -- Masahiko Iwamoto / Junichi Katagiri (ATKK) -- v 2.50 12/15/08 : Change the MIB version to v2.50 -- Add enum type to atiStkSwPortNegotiation -- Add atiStkSwCPUInfoTable for supporting the cpu utilization. -- -- Nelson Ho (ATI) v 2.51 01/22/09 : Add atiStkSwSysNumOfModuleInStack -- and atiStkSwStackTopologyChangeTrap -- -- Masahiko Iwamoto (ATKK)v 2.52 03/02/09 : Change the MIB version to v2.52 -- Add enum type to ATIPortType for XFP support -- Add new OID for model 9424T -- Add new OID for model 9424T POE -- Add new OID for model 9424TL -- -- Nelson Ho (ATI) v 2.53 03/14/09 : -- Add atiStkSwBPDUGuardIsTriggeredTrap -- -- Junichi Katagiri (ATKK)v 2.54 03/23/09 : Add atiStkSwMemoryGroup -- -- Junichi Katagiri (ATKK)v 2.55 08/20/09 : Add new MIB table -- atiStkSwPortLoopDetectCurrentTable, and new traps for Loop Detection. -- AtiStackSwitch-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, MODULE-IDENTITY,OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter64, Counter32, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, RowStatus, TruthValue, MacAddress FROM SNMPv2-TC enterprises FROM RFC1155-SMI; alliedTelesyn MODULE-IDENTITY LAST-UPDATED "200407220000Z" ORGANIZATION "Allied Telesyn International" CONTACT-INFO "Allied Telesyn International" DESCRIPTION "Private MIB for ATI layer 2 stackable switches. This MIB can be used in Windows and UNIX environments." ::= { enterprises 207 } -- OID tree for Allied Telesyn MIBs mibObject OBJECT IDENTIFIER ::= { alliedTelesyn 8 } atiStkSwMib OBJECT IDENTIFIER ::= { mibObject 17 } -- MODULE IDENTITY for the private mib -- AtiProductType AtiProductType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used to specify the syntax of objects describing the hardware product type." SYNTAX INTEGER { other (1), at8324 (2), at8316F-MT (3), at8316F-VF (4), at8316F-SC (5), at8524M (6), at8550GB (7), at8516F (8), at8550SP (9), at9424T-SP (10), at9424T-GB (11), at9408LC-SP (12), at8524-POE (13), at9424Ti-SP (14), at9448Ts-XP (15), at9448Ts (16), at9448T-SP (17), at9424Ts-XP (18), at9424Ts (19), -- at8588-SC (20) this is a reminder that the OID is being used at9424T (21), at9424T-POE (22), at9424TL (23) } -- AtiPortType AtiPortType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used to specify the syntax of objects describing the hardware port type." SYNTAX INTEGER { other (1), notPresent (2), mgmt (3), tenBaseT (4), hundredBaseT (5), hundredBaseFX-VF (6), hundredBaseFX-MT (7), hundredBaseFX-SC (8), hundredBaseFX-LC (9), thousandBaseT (10), gigabit (11), gigabitSX (12), gigabitSX-SC (13), gigabitSX-MT (14), gigabitSX-VF (15), gigabitSX-LC (16), gigabitLX (17), gigabitLX-SC (18), gigabitLX-MT (19), gigabitLX-VF (20), gigabitLX-LC (21), sm15 (22), ten-gigabit (23) } AtiUplinkType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This data type is used to specify the syntax of objects confirming to the Allied Telesyn, Inc. uplink types. These are primarily used in the 85xx and 94xx family of switches. For all other releases, this may not be applicable. Please confirm with the release notes for additional information on these types." SYNTAX INTEGER { notPresent (1), other (2), applique-at-45-sc-sm (3), applique-at-45-sc (4), applique-at-45-mt (5), applique-at-46 (6), applique-at-47 (7), sfp (8), gbic (9), xfp (10) } -- OID tree for Allied Telesyn Layer-2 switches atiProduct OBJECT IDENTIFIER ::= { alliedTelesyn 1 } swhub OBJECT IDENTIFIER ::= { atiProduct 4 } at-8324 OBJECT IDENTIFIER ::= { swhub 37 } at-8316F OBJECT IDENTIFIER ::= { swhub 77 } at-8524M OBJECT IDENTIFIER ::= { swhub 98 } at-8550GB OBJECT IDENTIFIER ::= { swhub 99 } at-8516F OBJECT IDENTIFIER ::= { swhub 100 } at-8550SP OBJECT IDENTIFIER ::= { swhub 104 } at-9424T-SP OBJECT IDENTIFIER ::= { swhub 105 } at-9424T-GB OBJECT IDENTIFIER ::= { swhub 112 } at-8524POE OBJECT IDENTIFIER ::= { swhub 113 } at-9408LC-SP OBJECT IDENTIFIER ::= { swhub 117 } at-9424Ti-SP OBJECT IDENTIFIER ::= { swhub 118 } at-9448Ts-XP OBJECT IDENTIFIER ::= { swhub 119 } at-9448Ts OBJECT IDENTIFIER ::= { swhub 130 } at-9448T-SP OBJECT IDENTIFIER ::= { swhub 131 } at-9424Ts-XP OBJECT IDENTIFIER ::= { swhub 132 } at-9424Ts OBJECT IDENTIFIER ::= { swhub 133 } -- at-8588-SC OBJECT IDENTIFIER ::= { swhub 134 } at-9424T OBJECT IDENTIFIER ::= { swhub 146 } at-9424TPOE OBJECT IDENTIFIER ::= { swhub 152 } at-9424TL OBJECT IDENTIFIER ::= { swhub 153 } -- Groups supported in this MIB atiStkSwSysGroup OBJECT IDENTIFIER ::= { atiStkSwMib 1 } atiStkSwPortGroup OBJECT IDENTIFIER ::= { atiStkSwMib 2 } atiStkSwVlanGroup OBJECT IDENTIFIER ::= { atiStkSwMib 3 } atiStkSwMacAddrGroup OBJECT IDENTIFIER ::= { atiStkSwMib 4 } atiStkSwEthStatsGroup OBJECT IDENTIFIER ::= { atiStkSwMib 5 } atiStkSwTrapsGroup OBJECT IDENTIFIER ::= { atiStkSwMib 6 } atiStkSwQoSGroup OBJECT IDENTIFIER ::= { atiStkSwMib 7 } atiStkSwTrunkGroup OBJECT IDENTIFIER ::= { atiStkSwMib 8 } atiStkSwACLGroup OBJECT IDENTIFIER ::= { atiStkSwMib 9 } -- The atiStkSwSysGroup atiStkSwSysConfig OBJECT IDENTIFIER ::= { atiStkSwSysGroup 1 } atiStkSwSysNwMgmt OBJECT IDENTIFIER ::= { atiStkSwSysGroup 2 } -- Defined below atiStkSwSysProductInfoTable OBJECT IDENTIFIER ::= { atiStkSwSysGroup 3 } -- atiStkSwSysUplinkInfoTable OBJECT IDENTIFIER ::= { atiStkSwSysGroup 4 } atiStkSwSysSystemTimeConfig OBJECT IDENTIFIER ::= { atiStkSwSysGroup 5 } atiStkSwSysInfoGroup OBJECT IDENTIFIER ::= { atiStkSwSysGroup 6 } atiStkSwSysMgmtACLGroup OBJECT IDENTIFIER ::= { atiStkSwSysGroup 7 } -- atiStkSwSysConfig atiStkSwSysReset OBJECT-TYPE SYNTAX INTEGER { no-reset (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'reset' will cause the switch to perform a soft reboot. Setting this object to 'no-reset' will have no effect." ::= { atiStkSwSysConfig 1 } atiStkSwSysIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the switch." ::= { atiStkSwSysConfig 2 } atiStkSwSysSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet mask of the switch." ::= { atiStkSwSysConfig 3 } atiStkSwSysGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the gateway for the switch." ::= { atiStkSwSysConfig 4 } atiStkSwSysIpAddressStatus OBJECT-TYPE SYNTAX INTEGER { fromDhcp (1), fromBootp (2), static (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies how the IP address, subnet mask and the gateway address currently in use on the switch was obtained/configured." ::= { atiStkSwSysConfig 5 } atiStkSwSysDnsServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the IP address of the DNS server for the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysConfig 6 } atiStkSwSysDefaultDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the default domain name for the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysConfig 7 } atiStkSwSysNumberOfModules OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives a count of the number of modules present in the stackable switch." ::= { atiStkSwSysConfig 8 } atiStkSwSysSpanningTreeStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'enable' will enable spanning tree protocol on the switch. Setting this object to 'disable' will disable spanning tree protocol on the switch. Select the spanning tree protocol version using the object 'atiStkSwSysSpanningTreeVersion'." ::= { atiStkSwSysConfig 9 } atiStkSwSysSpanningTreeVersion OBJECT-TYPE SYNTAX INTEGER { rstp (1), stp (2), mstp (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The object can be used to select the version of spanning tree protocol running on the switch." ::= { atiStkSwSysConfig 10 } atiStkSwSysAction OBJECT-TYPE SYNTAX INTEGER { saveConfig (1), reset (2), defaultConfig (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the following actions that apply to the switch: saveConfig - Save the current switch configuration. reset - Reboot the switch. defaultConfig - Restore default switch configuration. The switch is automatically rebooted after this operation. Note that this object returns a zero value when doing a Get operation." ::= { atiStkSwSysConfig 11 } atiStkSwSysNumOfModuleInStack OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the number of stacking modules in the stack." ::= { atiStkSwSysConfig 12 } -- atiStkSwSysNwMgmt atiStkSwSysTrapRecv1 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object specifies the IP address of the management station #1 to which traps are sent by the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysNwMgmt 1 } atiStkSwSysTrapRecv2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object specifies the IP address of the management station #2 to which traps are sent by the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysNwMgmt 2 } atiStkSwSysTrapRecv3 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object specifies the IP address of the management station #3 to which traps are sent by the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysNwMgmt 3 } atiStkSwSysTrapRecv4 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object specifies the IP address of the management station #4 to which traps are sent by the switch. This MIB is not applicable to the 85xx and 94xx family of ATI switches." ::= { atiStkSwSysNwMgmt 4 } -- atiStkSwSysProductInfoTable atiStkSwSysProductInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwSysProductInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules present in the switch stack and their associated hardware information." ::= { atiStkSwSysGroup 3 } atiStkSwSysProductInfoEntry OBJECT-TYPE SYNTAX AtiStkSwSysProductInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwSysProductInfoTable' that describes the hardware informaton for a module present in the switch stack." INDEX { atiStkSwSysModuleId } ::= { atiStkSwSysProductInfoTable 1 } AtiStkSwSysProductInfoEntry ::= SEQUENCE { atiStkSwSysModuleId Integer32, atiStkSwSysProductType AtiProductType, atiStkSwSysMacAddress MacAddress, atiStkSwSysSwName DisplayString, atiStkSwSysSwVersion DisplayString, atiStkSwSysHwName DisplayString, atiStkSwSysHwRevision DisplayString, atiStkSwSysSerialNumber DisplayString, atiStkSwSysTotalPortCount Integer32, atiStkSwSysBasePortType AtiPortType, atiStkSwSysBasePortCount Integer32, atiStkSwSysUplinkAModelName DisplayString, atiStkSwSysUplinkAPortType AtiPortType, atiStkSwSysUplinkAPortCount Integer32, atiStkSwSysUplinkAPortIdBase Integer32, atiStkSwSysUplinkAPortIdLimit Integer32, atiStkSwSysUplinkBModelName DisplayString, atiStkSwSysUplinkBPortType AtiPortType, atiStkSwSysUplinkBPortCount Integer32, atiStkSwSysUplinkBPortIdBase Integer32, atiStkSwSysUplinkBPortIdLimit Integer32, atiStkSwSysRPSPresent INTEGER, atiStkSwSysRPSState INTEGER, atiStkSwSysDCState INTEGER, atiStkSwSysTemperatureLimitValue Integer32 } atiStkSwSysModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this module." ::= { atiStkSwSysProductInfoEntry 1 } atiStkSwSysProductType OBJECT-TYPE SYNTAX AtiProductType MAX-ACCESS read-only STATUS current DESCRIPTION "The product type of this module." ::= { atiStkSwSysProductInfoEntry 2 } atiStkSwSysMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The system MAC address used by this module." ::= { atiStkSwSysProductInfoEntry 3 } atiStkSwSysSwName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the system software running on this module." ::= { atiStkSwSysProductInfoEntry 4 } atiStkSwSysSwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the system software running on this module." ::= { atiStkSwSysProductInfoEntry 5 } atiStkSwSysHwName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the module hardware." ::= { atiStkSwSysProductInfoEntry 6 } atiStkSwSysHwRevision OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The revision number of the module hardware." ::= { atiStkSwSysProductInfoEntry 7 } atiStkSwSysSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the module." ::= { atiStkSwSysProductInfoEntry 8 } atiStkSwSysTotalPortCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of ports (base and uplink) present on this module." ::= { atiStkSwSysProductInfoEntry 9 } atiStkSwSysBasePortType OBJECT-TYPE SYNTAX AtiPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware type of a base port on this module." ::= { atiStkSwSysProductInfoEntry 10 } atiStkSwSysBasePortCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of base ports present on this module." ::= { atiStkSwSysProductInfoEntry 11 } atiStkSwSysUplinkAModelName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name of the uplink #A connector of this module." ::= { atiStkSwSysProductInfoEntry 12 } atiStkSwSysUplinkAPortType OBJECT-TYPE SYNTAX AtiPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware type of a port present in the uplink #A connector of this module." ::= { atiStkSwSysProductInfoEntry 13 } atiStkSwSysUplinkAPortCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of uplink #A ports present on this module." ::= { atiStkSwSysProductInfoEntry 14 } atiStkSwSysUplinkAPortIdBase OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the first port in uplink #A of this module." ::= { atiStkSwSysProductInfoEntry 15 } atiStkSwSysUplinkAPortIdLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the last port in uplink #A of this module." ::= { atiStkSwSysProductInfoEntry 16 } atiStkSwSysUplinkBModelName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name of the uplink #B connector of this module." ::= { atiStkSwSysProductInfoEntry 17 } atiStkSwSysUplinkBPortType OBJECT-TYPE SYNTAX AtiPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware type of a port present in the uplink #B connector of this module." ::= { atiStkSwSysProductInfoEntry 18 } atiStkSwSysUplinkBPortCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of uplink #B ports present on this module." ::= { atiStkSwSysProductInfoEntry 19 } atiStkSwSysUplinkBPortIdBase OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the first port in uplink #B of this module." ::= { atiStkSwSysProductInfoEntry 20 } atiStkSwSysUplinkBPortIdLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the last port in uplink #B of this module." ::= { atiStkSwSysProductInfoEntry 21 } atiStkSwSysRPSPresent OBJECT-TYPE SYNTAX INTEGER { connected (1), disconnected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object shows the presence of the RPS (Redundant Power Supply.) Note: This is not available on the 83xx switch family." ::= { atiStkSwSysProductInfoEntry 22 } atiStkSwSysRPSState OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object shows if the connected RPS is on (supplying power) or off (not supplying power) to this switch. Note: This is not available on the 83xx switch family." ::= { atiStkSwSysProductInfoEntry 23 } atiStkSwSysDCState OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object shows if the main Power Source is DC. Note: If this is Off and RPS State is off, then the AC Main is supllying power. Note: This is not available on the 83xx switch family." ::= { atiStkSwSysProductInfoEntry 24 } atiStkSwSysTemperatureLimitValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the temperature value when it is above the Warning or Error limits." ::= { atiStkSwSysProductInfoEntry 25 } -- atiStkSwSysUplinkInfoTable atiStkSwSysUplinkInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwSysUplinkInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of uplinks present in the switch stack and their associated hardware information." ::= { atiStkSwSysGroup 4 } atiStkSwSysUplinkInfoEntry OBJECT-TYPE SYNTAX AtiStkSwSysUplinkInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwSysUplinkInfoTable' that describes the hardware informaton for a uplink present in the switch stack. **Note:This table may only be available with 94xx series of switches. Please confirm your release notes for the support of this table.**" INDEX { atiStkSwSysUplinkModuleId, atiStkSwSysUplinkPortId } ::= { atiStkSwSysUplinkInfoTable 1 } AtiStkSwSysUplinkInfoEntry ::= SEQUENCE { atiStkSwSysUplinkModuleId Integer32, atiStkSwSysUplinkPortId Integer32, atiStkSwSysUplinkSetup INTEGER, atiStkSwSysUplinkType AtiUplinkType, atiStkSwSysUplinkDetails DisplayString, atiStkSwSysUplinkPortType AtiPortType } atiStkSwSysUplinkModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this module." ::= { atiStkSwSysUplinkInfoEntry 1 } atiStkSwSysUplinkPortId OBJECT-TYPE SYNTAX Integer32(1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID (port number) of the this port (uplink) of this module." ::= { atiStkSwSysUplinkInfoEntry 2 } atiStkSwSysUplinkSetup OBJECT-TYPE SYNTAX INTEGER { fixed (1), pluggable (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The fixation of the uplink. Fixed types are GBICs, SFPs or XFPs that are an integral part of the sytem. Disjoint items are applique or module slots that are determined purely by the attached device." ::= { atiStkSwSysUplinkInfoEntry 3 } atiStkSwSysUplinkType OBJECT-TYPE SYNTAX AtiUplinkType MAX-ACCESS read-only STATUS current DESCRIPTION "The module type of the uplink connector of this module." ::= { atiStkSwSysUplinkInfoEntry 4 } atiStkSwSysUplinkDetails OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field will provide additional details to the Uplink. For GBIC, SFP or XFP, it may contain information on the installed devices (e.g. 1000-SX, 1000-T, etc). For applique types, it may have the name (e.g. A-47) and other specific information that may be useful in managing the device." ::= { atiStkSwSysUplinkInfoEntry 5 } atiStkSwSysUplinkPortType OBJECT-TYPE SYNTAX AtiPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware type of a port present in the uplink connector of this module. " ::= { atiStkSwSysUplinkInfoEntry 6 } -- The system time group atiStkSwSysCurrentTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specify the current time of the system. The user can change the time by providing the string format as an input, e.g. HH:MM:SS." ::= { atiStkSwSysSystemTimeConfig 1 } atiStkSwSysCurrentDate OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specify the current time of the system. The user can change the date by providing the string format as an input, e.g. DD:MM:YYYY." ::= { atiStkSwSysSystemTimeConfig 2 } atiStkSwSysSNTPStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable the SNTP status." ::= { atiStkSwSysSystemTimeConfig 3 } atiStkSwSysSNTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The ipaddress of the SNTP Server." ::= { atiStkSwSysSystemTimeConfig 4 } atiStkSwSysSNTPUTCOffset OBJECT-TYPE SYNTAX Integer32 (-12..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the UTC Offset value within the range from -12 to 12 in hours." ::= { atiStkSwSysSystemTimeConfig 5 } atiStkSwSysSNTPDSTStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disble the Daylight Saving Time." ::= { atiStkSwSysSystemTimeConfig 6 } atiStkSwSysSNTPPollingInterval OBJECT-TYPE SYNTAX Integer32 (60..1200) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the interval for polling the SNTP Server. The polling time range is between 60 and 1200 in seconds." ::= { atiStkSwSysSystemTimeConfig 7 } atiStkSwSysSNTPLastDelta OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display the last adjustment to system done in seconds." ::= { atiStkSwSysSystemTimeConfig 8 } -- The atiStkSwSysInfoGroup -- System Temperature Information Table atiStkSwTemperatureInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwTemperatureInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of system temperature information present in the switch stack including voltage and temperature." ::= { atiStkSwSysInfoGroup 1 } atiStkSwTemperatureInfoEntry OBJECT-TYPE SYNTAX AtiStkSwTemperatureInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwTemperatureInfoTable' that describes the hardware informaton for a module present in the switch stack." INDEX { atiStkSwTemperatureInfoModuleId } ::= { atiStkSwTemperatureInfoTable 1 } AtiStkSwTemperatureInfoEntry ::= SEQUENCE { atiStkSwTemperatureInfoModuleId Integer32, atiStkSwTemperatureInfoTemperature DisplayString } atiStkSwTemperatureInfoModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of a switch, it also used as an index of the table." ::= { atiStkSwTemperatureInfoEntry 1 } atiStkSwTemperatureInfoTemperature OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the device in Celcius." ::= { atiStkSwTemperatureInfoEntry 2 } -- The System Fan Information Table atiStkSwFanInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwFanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information for all the fans present in the switch." ::= { atiStkSwSysInfoGroup 2 } atiStkSwFanInfoEntry OBJECT-TYPE SYNTAX AtiStkSwFanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwFanInfoTable' that describes the informaton for a specific fan in the switch." INDEX { atiStkSwFanInfoModuleId, atiStkSwFanInfoFanId } ::= { atiStkSwFanInfoTable 1 } AtiStkSwFanInfoEntry ::= SEQUENCE { atiStkSwFanInfoModuleId Integer32, atiStkSwFanInfoFanId Integer32, atiStkSwFanInfoState DisplayString, atiStkSwFanInfoSpeed DisplayString } atiStkSwFanInfoModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwFanInfoEntry 1 } atiStkSwFanInfoFanId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The fan Id of the switch." ::= { atiStkSwFanInfoEntry 2 } atiStkSwFanInfoState OBJECT-TYPE SYNTAX DisplayString (SIZE(1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the fan running, either normal or off." ::= { atiStkSwFanInfoEntry 3 } atiStkSwFanInfoSpeed OBJECT-TYPE SYNTAX DisplayString (SIZE(1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of a fan." ::= { atiStkSwFanInfoEntry 4 } -- The System Voltage Information Table atiStkSwVoltageInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwVoltageInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of system Voltage information." ::= { atiStkSwSysInfoGroup 3 } atiStkSwVoltageInfoEntry OBJECT-TYPE SYNTAX AtiStkSwVoltageInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwVoltageInfoTable' that describes the Voltage informaton for the switch." INDEX { atiStkSwVoltageInfoModuleId, atiStkSwVoltageInfoIndex } ::= { atiStkSwVoltageInfoTable 1 } AtiStkSwVoltageInfoEntry ::= SEQUENCE { atiStkSwVoltageInfoModuleId Integer32, atiStkSwVoltageInfoIndex Integer32, atiStkSwVoltageInfoLevel DisplayString, atiStkSwVoltageInfoMeasured DisplayString } atiStkSwVoltageInfoModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwVoltageInfoEntry 1 } atiStkSwVoltageInfoIndex OBJECT-TYPE SYNTAX Integer32(1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the voltage table." ::= { atiStkSwVoltageInfoEntry 2 } atiStkSwVoltageInfoLevel OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage input level." ::= { atiStkSwVoltageInfoEntry 3 } atiStkSwVoltageInfoMeasured OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current voltage." ::= { atiStkSwVoltageInfoEntry 4 } -- The System CPU Information Table atiStkSwCPUInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwCPUInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about the cpu utilization over different periods of time." ::= { atiStkSwSysInfoGroup 4 } atiStkSwCPUInfoEntry OBJECT-TYPE SYNTAX AtiStkSwCPUInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwCPUInfoTable' that describes the cpu informaton for the switch." INDEX { atiStkSwCPUInfoModuleId } ::= { atiStkSwCPUInfoTable 1 } AtiStkSwCPUInfoEntry ::= SEQUENCE { atiStkSwCPUInfoModuleId Integer32, atiStkSwCPUInfoAvgLastMinute Integer32, atiStkSwCPUInfoAvgLast20Seconds Integer32, atiStkSwCPUInfoAvgSecond Integer32 } atiStkSwCPUInfoModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwCPUInfoEntry 1 } atiStkSwCPUInfoAvgLastMinute OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Average CPU utilization over the past minute. Expressed as a percentage." ::= { atiStkSwCPUInfoEntry 2 } atiStkSwCPUInfoAvgLast20Seconds OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Average CPU utilization over the past twenty seconds. Expressed as a percentage." ::= { atiStkSwCPUInfoEntry 3 } atiStkSwCPUInfoAvgSecond OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Average CPU utilization over the past second. Expressed as a percentage." ::= { atiStkSwCPUInfoEntry 4 } -- The Memory Information atiStkSwMemoryGroup OBJECT IDENTIFIER ::= { atiStkSwSysInfoGroup 5 } -- Memory information table atiStkSwMemoryInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwMemoryInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about memory size on module." ::= { atiStkSwMemoryGroup 1 } atiStkSwMemoryInfoEntry OBJECT-TYPE SYNTAX AtiStkSwMemoryInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwMemoryInfoTable' that describes the memory size for the switch." INDEX { atiStkSwMemoryInfoModuleId } ::= { atiStkSwMemoryInfoTable 1 } AtiStkSwMemoryInfoEntry ::= SEQUENCE { atiStkSwMemoryInfoModuleId Integer32, atiStkSwMemoryInfoTotalBuffers Integer32 } atiStkSwMemoryInfoModuleId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwMemoryInfoEntry 1 } atiStkSwMemoryInfoTotalBuffers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Size of memory buffer(kB)." ::= { atiStkSwMemoryInfoEntry 2 } -- The memory pool information atiStkSwMemoryPoolTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwMemoryPoolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about each memory pool." ::= { atiStkSwMemoryGroup 2 } atiStkSwMemoryPoolEntry OBJECT-TYPE SYNTAX AtiStkSwMemoryPoolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwMemoryPoolTable' that describes the total and free size of each memory pool." INDEX { atiStkSwMemoryPoolModuleId, atiStkSwMemoryPoolIndex } ::= { atiStkSwMemoryPoolTable 1 } AtiStkSwMemoryPoolEntry ::= SEQUENCE { atiStkSwMemoryPoolModuleId Integer32, atiStkSwMemoryPoolIndex Integer32, atiStkSwMemoryPoolName DisplayString, atiStkSwMemoryPoolTotal Integer32, atiStkSwMemoryPoolFree Integer32 } atiStkSwMemoryPoolModuleId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwMemoryPoolEntry 1 } atiStkSwMemoryPoolIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of memory pool." ::= { atiStkSwMemoryPoolEntry 2 } atiStkSwMemoryPoolName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of memory pool." ::= { atiStkSwMemoryPoolEntry 3 } atiStkSwMemoryPoolTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Size of memory pool(kB)." ::= { atiStkSwMemoryPoolEntry 4 } atiStkSwMemoryPoolFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Size of free memory pool(kB)." ::= { atiStkSwMemoryPoolEntry 5 } -- The communication buffers information atiStkSwMemoryComBuffersTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwMemoryComBuffersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about communication buffers on module." ::= { atiStkSwMemoryGroup 3 } atiStkSwMemoryComBuffersEntry OBJECT-TYPE SYNTAX AtiStkSwMemoryComBuffersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwMemoryComBuffersTable' that describes the communication buffers." INDEX { atiStkSwMemoryComBuffersModuleId } ::= { atiStkSwMemoryComBuffersTable 1 } AtiStkSwMemoryComBuffersEntry ::= SEQUENCE { atiStkSwMemoryComBuffersModuleId Integer32, atiStkSwMemoryTotalComBuffers Integer32, atiStkSwMemoryFreeComBuffers Integer32 } atiStkSwMemoryComBuffersModuleId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The module Id of the switch." ::= { atiStkSwMemoryComBuffersEntry 1 } atiStkSwMemoryTotalComBuffers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of communication buffers." ::= { atiStkSwMemoryComBuffersEntry 2 } atiStkSwMemoryFreeComBuffers OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Free communication buffers still available." ::= { atiStkSwMemoryComBuffersEntry 3 } -- atiStkSwSysMgmtACL Group atiStkSwSysMgmtACLStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable management ACL feature." ::= { atiStkSwSysMgmtACLGroup 1 } atiStkSwSysMgmtACLConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwSysMgmtACLConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of MgmtACLs present in the switch stack and their associated hardware information." ::= { atiStkSwSysMgmtACLGroup 2 } atiStkSwSysMgmtACLConfigEntry OBJECT-TYPE SYNTAX AtiStkSwSysMgmtACLConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwSysMgmtACLConfigTable' that allow the user controls which management stations can remotely manage the device using the Telnet application protocol or a web browser." INDEX { atiStkSwSysMgmtACLConfigModuleId, atiStkSwSysMgmtACLConfigId } ::= { atiStkSwSysMgmtACLConfigTable 1 } AtiStkSwSysMgmtACLConfigEntry ::= SEQUENCE { atiStkSwSysMgmtACLConfigModuleId Integer32, atiStkSwSysMgmtACLConfigId Integer32, atiStkSwSysMgmtACLConfigIpAddr IpAddress, atiStkSwSysMgmtACLConfigMask IpAddress, atiStkSwSysMgmtACLConfigApplication BITS, atiStkSwSysMgmtACLConfigRowStatus RowStatus } atiStkSwSysMgmtACLConfigModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of this module." ::= { atiStkSwSysMgmtACLConfigEntry 1 } atiStkSwSysMgmtACLConfigId OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the Management ACL Table for this module." ::= { atiStkSwSysMgmtACLConfigEntry 2 } atiStkSwSysMgmtACLConfigIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP Address of the specific management station." ::= { atiStkSwSysMgmtACLConfigEntry 3 } atiStkSwSysMgmtACLConfigMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet mask of the IP Address." ::= { atiStkSwSysMgmtACLConfigEntry 4 } atiStkSwSysMgmtACLConfigApplication OBJECT-TYPE SYNTAX BITS { telnet (0), web (1), ping (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specify which interface the user want the management station to be able to use when managing the switch. The options are : telnet, web, ping, all. Note that the enum value correspond to the bit position of the mask." ::= { atiStkSwSysMgmtACLConfigEntry 5 } atiStkSwSysMgmtACLConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The Row Status of the Mgmt ACL table. " ::= { atiStkSwSysMgmtACLConfigEntry 6 } -- The atiStkSwPortGroup -- Defined Below atiStkSwPortConfigTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 1 } atiStkSwPortMirroringConfig OBJECT IDENTIFIER ::= { atiStkSwPortGroup 2 } atiStkSwPortSecurityConfig OBJECT IDENTIFIER ::= { atiStkSwPortGroup 3 } -- Define Below atiStkSwPortIntrusionDetectionTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 4 } -- Defined Below atiStkPortSecurityConfigTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 5 } atiStkDOSConfig OBJECT IDENTIFIER ::= { atiStkSwPortGroup 6 } --atiStkSwIntrusionAttackTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 7 } --atiStkSwPortStormDetectCurrentTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 8 } --atiStkSwPortLoopDetectCurrentTable OBJECT IDENTIFIER ::= { atiStkSwPortGroup 9 } -- atiStkSwPortConfigTable atiStkSwPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of physical ports present in the switch and their associated attributes." ::= { atiStkSwPortGroup 1 } atiStkSwPortConfigEntry OBJECT-TYPE SYNTAX AtiStkSwPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwPortConfigTable' that describes the attributes associated with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwPortConfigTable 1 } AtiStkSwPortConfigEntry ::= SEQUENCE { atiStkSwModuleId Integer32, atiStkSwPortId Integer32, atiStkSwPortName DisplayString, atiStkSwPortState INTEGER, atiStkSwPortLinkState INTEGER, atiStkSwPortNegotiation INTEGER, atiStkSwPortSpeed INTEGER, atiStkSwPortDuplexStatus INTEGER, atiStkSwPortFlowControl INTEGER, atiStkSwPortBackPressure INTEGER, atiStkSwPortPriority INTEGER, atiStkSwPortBroadcastProcessing INTEGER, atiStkSwPortMDIO INTEGER, atiStkSwPortHOLLimit Integer32, atiStkSwPortBackPressureLimit Integer32, atiStkSwPortSTPState INTEGER } atiStkSwModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ID of a module present in the switch stack." ::= { atiStkSwPortConfigEntry 1 } atiStkSwPortId OBJECT-TYPE SYNTAX Integer32(1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ID of a port present on a given module." ::= { atiStkSwPortConfigEntry 2 } atiStkSwPortName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user-defined ASCII name of the port." ::= { atiStkSwPortConfigEntry 3 } atiStkSwPortState OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to either enabled or disabled. This object can be read to obtain the current state of the port." ::= { atiStkSwPortConfigEntry 4 } atiStkSwPortLinkState OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the link state on this port." ::= { atiStkSwPortConfigEntry 5 } atiStkSwPortNegotiation OBJECT-TYPE SYNTAX INTEGER { autosense (1), forceHalfDuplex-10M (2), forceHalfDuplex-100M (3), forceHalfDuplex-1G (4), forceFullDuplex-10M (5), forceFullDuplex-100M (6), forceFullDuplex-1G (7), autoHalfDuplex-10M (8), autoHalfDuplex-100M (9), autoFullDuplex-10M (10), autoFullDuplex-100M (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows an admin request to configure the port to either autosense or one of the different speed-duplex combinations." ::= { atiStkSwPortConfigEntry 6 } atiStkSwPortSpeed OBJECT-TYPE SYNTAX INTEGER { unknown (1), speed-10M (2), speed-100M (3), speed-1G (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current speed of the port." ::= { atiStkSwPortConfigEntry 7 } atiStkSwPortDuplexStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), halfDuplex (2), fullDuplex (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current duplex type used by the port." ::= { atiStkSwPortConfigEntry 8 } atiStkSwPortFlowControl OBJECT-TYPE SYNTAX INTEGER { unknown(1), disable (2), enable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to enable/disable flow control on the port. When enabled, flow control will be full duplex. Flow control is disabled by default." ::= { atiStkSwPortConfigEntry 9 } atiStkSwPortBackPressure OBJECT-TYPE SYNTAX INTEGER { unknown (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to enable/disable Back Pressure on the port. Back Pressure is disabled by default." ::= { atiStkSwPortConfigEntry 10 } atiStkSwPortPriority OBJECT-TYPE SYNTAX INTEGER { use-vlan-priority (1), override-and-use-low-priority (2), override-and-use-high-priority (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether packets flowing through this port use the associated VLAN priority or override the associated VLAN priority with either a high or a low priority. This MIB is not applicable to the 85xx and 94xx family of ATI switches. Note: These switch families support CoS/QoS." ::= { atiStkSwPortConfigEntry 11 } atiStkSwPortBroadcastProcessing OBJECT-TYPE SYNTAX INTEGER { discard-broadcasts (1), do-not-discard-broadcasts (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether the received broadcast packets should be processed or discarded. Broadcast packets are processed by default." ::= { atiStkSwPortConfigEntry 12 } atiStkSwPortMDIO OBJECT-TYPE SYNTAX INTEGER { mdi (1), mdix (2), auto-mdix (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the MDIO of this port for required cable connection type. For straight-through cable set to mdi and for cross-over cable set to mdix." ::= { atiStkSwPortConfigEntry 13 } atiStkSwPortHOLLimit OBJECT-TYPE SYNTAX Integer32(0..61440) MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows user to set the head of line blocking limit. Note (94xx): Range upto 8191 is supported for Gigabit Ports." ::= { atiStkSwPortConfigEntry 14 } atiStkSwPortBackPressureLimit OBJECT-TYPE SYNTAX Integer32(1..57344) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the MDIO of this port for required cable connection type. For straight-through cable set to mdi and for cross-over cable set to mdix. This limit can be used for both BackPressure and FlowControl Limits. Note: The range of 1 to 7935 is supported on the 94xx family." ::= { atiStkSwPortConfigEntry 15 } atiStkSwPortSTPState OBJECT-TYPE SYNTAX INTEGER { unknown (1), disabled (2), blocking (3), listening (4), learning (5), forwarding (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the spanning tree state on this port. This object is not applicable to 8300 series products. This object is not valid on the 9400 series of boxes." ::= { atiStkSwPortConfigEntry 16 } -- atiStkSwPortMirroringConfig atiStkSwPortMirroringState OBJECT-TYPE SYNTAX INTEGER { disabled (1), l2-enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether port mirroring is l2-enabled, or disabled on the switch. Note that, when enabled, both transmit and receive packets will be mirrored." ::= { atiStkSwPortMirroringConfig 1 } atiStkSwPortMirroringSourceModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the module ID of the source port that is mirrored. All packets transmitted and received on the source port will be mirrored onto the destination port (specified by 'atiStkSwPortMirroringDestinationModuleId' and 'atiStkSwPortMirroringDestinationPortId'). This object will be set to 0 when port mirroring is disabled. This object will have a default value of 1 (the master module ID) when mirroring is enabled. This is not available on the 85xx and 94xx series of switches." ::= { atiStkSwPortMirroringConfig 2 } atiStkSwPortMirroringSourcePortId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the port ID (on the module specified by 'atiStkSwPortMirroringSourceModuleId') of the source port that is mirrored. All packets transmitted and received on the source port will be mirrored onto the destination port (specified by 'atiStkSwPortMirroringDestinationModuleId' and 'atiStkSwPortMirroringDestinationPortId'). This object will be set to 0 when port mirroring is disabled. When mirroring is enabled, set this object to a non-zero value to activate mirroring. This is not available on the 85xx and 94xx series of switches." ::= { atiStkSwPortMirroringConfig 3 } atiStkSwPortMirroringDestinationModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the module ID of the destination port that mirrors the source port (specified by 'atiStkSwPortMirroringSourceModuleId' and 'atiStkSwPortMirroringSourcePortId'). All packets transmitted and received on the source port will be mirrored onto the destination port. This object will have a value of 0 when port mirroring is disabled. This object will have a default value of 1 (the master module ID) when mirroring is enabled. This is not available on the 85xx and 94xx series of switches" ::= { atiStkSwPortMirroringConfig 4 } atiStkSwPortMirroringDestinationPortId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the port ID (on the module specified by 'atiStkSwPortMirroringDestinationModuleId') of the destination port that mirrors the source port (specified by 'atiStkSwPortMirroringSourceModuleId' and 'atiStkSwPortMirroringSourcePortId'). All packets transmitted and received on the source port will be mirrored onto the destination port. This object will have a value of 0 when port mirroring is disabled. When mirroring is enabled, set this object to a non-zero value to activate mirroring." ::= { atiStkSwPortMirroringConfig 5 } atiStkSwPortMirroringSourceRxList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of ports that are mirrored for ingress traffic. All packets received on these ports will be mirrored onto the mirror port (atiStkSwPortMirroringDestinationPortId). It is in the format of a list of separated by comma. For example, '1, 4-7' represents the port number 1 ports from number 4 to 7. This object is not applicable to 8300 series products." ::= { atiStkSwPortMirroringConfig 6 } atiStkSwPortMirroringSourceTxList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of ports that are mirrored for egress traffic. All packets transmitted from these ports will be mirrored onto the mirror port (atiStkSwPortMirroringDestinationPortId). It is in the format of a list of separated by comma. For example, '1, 4-7' represents the port number 1 ports from number 4 to 7. This object is not applicable to 8300 series products." ::= { atiStkSwPortMirroringConfig 7 } -- atiStkSwPortSecurityConfig atiStkSwPortSecurityMode OBJECT-TYPE SYNTAX INTEGER { automatic (1), limited (2), secured (3), locked (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the type of port security configured on the switch. Setting this object to 'automatic(1)' allows the ports to learn new MAC addresses normally. In 'limited(2)' mode, only a limited number of addresses are learned per port. In 'secured(3)' mode, the administrator is responsible for configuring the MAC addresses manually per port. In 'locked(4)' mode, the ports stop learning new addresses and those addresses already learnt are locked. By default, port security is set to 'automatic(1)' mode." ::= { atiStkSwPortSecurityConfig 1 } -- atiStkSwPortIntrusionDetectionTable atiStkSwPortIntrusionDetectionTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwPortIntrusionDetectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules and their associated port security -related intrusion detection options. This table is valid only when 'atiStkSwPortSecurityMode' is set to a value other than 'automatic(1)'. This table object is not applicable to 8500 and 9400 series products. " ::= { atiStkSwPortGroup 4 } atiStkSwPortIntrusionDetectionEntry OBJECT-TYPE SYNTAX AtiStkSwPortIntrusionDetectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwPortIntrusionDetectionTable' that describes port security -related intruder detection configuration associated with a module." INDEX { atiStkSwModuleId } ::= { atiStkSwPortIntrusionDetectionTable 1 } AtiStkSwPortIntrusionDetectionEntry ::= SEQUENCE { atiStkSwPortIntrusionDetectionAction INTEGER, atiStkSwPortIntrusionDetectionPortList DisplayString } atiStkSwPortIntrusionDetectionAction OBJECT-TYPE SYNTAX INTEGER { do-nothing (1), send-trap-only (2), disable-port-and-send-trap (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the security action that should be taken when an intrusion is detected." ::= { atiStkSwPortIntrusionDetectionEntry 1 } atiStkSwPortIntrusionDetectionPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of ports on this module that participate in intrusion detection." ::= { atiStkSwPortIntrusionDetectionEntry 2 } -- atiStkPortSecurityConfigTable atiStkPortSecurityConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkPortSecurityConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the port security attributes of a list of physical ports present in the switch. This table object is not applicable to 8300 series products." ::= { atiStkSwPortGroup 5 } atiStkPortSecurityConfigEntry OBJECT-TYPE SYNTAX AtiStkPortSecurityConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkPortSecurityConfigTable' that describes the port security attributes associated with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkPortSecurityConfigTable 1 } AtiStkPortSecurityConfigEntry ::= SEQUENCE { atiStkPortSecurityMode INTEGER, atiStkPortSecurityThreshold Integer32, atiStkPortIntrusionAction INTEGER, atiStkPortIntrusionActionStatus INTEGER } atiStkPortSecurityMode OBJECT-TYPE SYNTAX INTEGER { automatic (1), limited (2), secured (3), locked (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the type of port security configured on the switch. Setting this object to 'automatic(1)' allows the ports to learn new MAC addresses normally. In 'limited(2)' mode, only a limited number of addresses are learned per port. In 'secured(3)' mode, the administrator is responsible for configuring the MAC addresses manually per port. In 'locked(4)' mode, the ports stop learning new addresses and those addresses already learnt are locked. By default, port security is set to 'automatic(1)' mode." ::= { atiStkPortSecurityConfigEntry 1 } atiStkPortSecurityThreshold OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the security threshold on this port. It is applicable only if the port security mode (specified by 'portSecurityMode') is set to 'limited(2)' mode." ::= { atiStkPortSecurityConfigEntry 2 } atiStkPortIntrusionAction OBJECT-TYPE SYNTAX INTEGER { discard (1), send-trap (2), disable-port (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the security action that should be taken when an intrusion is detected. By default, port intrusion action is set to 'discard' mode." ::= { atiStkPortSecurityConfigEntry 3 } atiStkPortIntrusionActionStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables or disables the security action specified by the 'portIntrusionAction'. By default, port intrusion action is disabled." ::= { atiStkPortSecurityConfigEntry 4 } -- atiStkDOSConfig -- DOS (Denial Of Service) is not applicable to 8300 series products. atiStkDOSConfigLANIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of LAN. This object is not applicable to 8300 series products." ::= { atiStkDOSConfig 1 } atiStkDOSConfigLANSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The subnet mask of LAN. This object is not applicable to 8300 series products." ::= { atiStkDOSConfig 2 } atiStkPortDOSAttackConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkPortDOSAttackConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the port DOS (denial of service) attack configuration attributes of a list of physical ports present in the switch. This table object is not applicable to 8300 series products." ::= { atiStkDOSConfig 3 } atiStkPortDOSAttackConfigEntry OBJECT-TYPE SYNTAX AtiStkPortDOSAttackConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkPortDOSAttackConfigTable' that describes the port DOS attack configuration attributes associated with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortDOSAttackType } ::= { atiStkPortDOSAttackConfigTable 1 } AtiStkPortDOSAttackConfigEntry ::= SEQUENCE { atiStkSwPortDOSAttackType INTEGER, atiStkSwPortDOSAttackActionStatus INTEGER, atiStkSwPortDOSAttackMirrorPort Integer32, atiStkSwPortDOSAttackMirrorPortStatus INTEGER } atiStkSwPortDOSAttackType OBJECT-TYPE SYNTAX INTEGER { syn-flood (1), smurf (2), land (3), ip-option (4), teardrop (5), ping-of-death (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the type of Port DOS attack configured on the switch." ::= { atiStkPortDOSAttackConfigEntry 1 } atiStkSwPortDOSAttackActionStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables or disables the port DOS action specified by the 'atiStkSwPortDOSAttackType'. By default, port DOS attack action is disabled." ::= { atiStkPortDOSAttackConfigEntry 2 } atiStkSwPortDOSAttackMirrorPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This object specifies the mirror port number to which the packet are to be mirrored for the DOS attack as specified by atiStkSwPortDOSAttackType." ::= { atiStkPortDOSAttackConfigEntry 3 } atiStkSwPortDOSAttackMirrorPortStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables or disables mirroring of attack packets. If enabled, all potential attack packets are mirrored to the port specified by atiStkSwPortMirroringDestinationModuleId and atiStkSwPortMirroringDestinationPortId. The object atiStkSwPortMirroringState should also be set to l2-enabled for mirroring to work." ::= { atiStkPortDOSAttackConfigEntry 4 } -- The atiStkSwIntrusionAttackTable atiStkSwIntrusionAttackTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwIntrusionAttackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwIntrusionAttackTable' that describes the intruder attack associated with a physical port present in the switch." ::= { atiStkSwPortGroup 7 } atiStkSwIntrusionAttackEntry OBJECT-TYPE SYNTAX AtiStkSwIntrusionAttackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwIntrusionAttackTable' that describes the intruder attack associated with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwIntrusionAttackTable 1 } AtiStkSwIntrusionAttackEntry ::= SEQUENCE { atiStkSwIntruderAttackVlanId Integer32, atiStkSwIntruderAttackMacAddr MacAddress } atiStkSwIntruderAttackVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the intruding VlanId on the port for this module." ::= { atiStkSwIntrusionAttackEntry 1 } atiStkSwIntruderAttackMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the intruding MAC address on the port for this module." ::= { atiStkSwIntrusionAttackEntry 2 } -- atiStkSwPortStormDetectCurrentTable atiStkSwPortStormDetectCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwPortStormDetectCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current Storm Detection informations of a list of physical ports present in the switch." ::= { atiStkSwPortGroup 8 } atiStkSwPortStormDetectCurrentEntry OBJECT-TYPE SYNTAX AtiStkSwPortStormDetectCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwPortStormDetectCurrentTable' that describes the current Storm Detection informations with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwPortStormDetectCurrentTable 1 } AtiStkSwPortStormDetectCurrentEntry ::= SEQUENCE { atiStkSwPortStormDetectCurrentHighStatus INTEGER, atiStkSwPortStormDetectCurrentHighAction INTEGER, atiStkSwPortStormDetectCurrentHighExpiry Integer32, atiStkSwPortStormDetectCurrentLowStatus INTEGER, atiStkSwPortStormDetectCurrentLowAction INTEGER, atiStkSwPortStormDetectCurrentLowExpiry Integer32 } atiStkSwPortStormDetectCurrentHighStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), normal (2), detected (3), blocking (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current high rate status of Storm Detection." ::= { atiStkSwPortStormDetectCurrentEntry 1 } atiStkSwPortStormDetectCurrentHighAction OBJECT-TYPE SYNTAX INTEGER { unknown (1), none (2), port-disabled (3), linkdown (4), broadcast-discard (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current high rate action by Storm Detected." ::= { atiStkSwPortStormDetectCurrentEntry 2 } atiStkSwPortStormDetectCurrentHighExpiry OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the remaining time(sec) to back to normal status from blocking status of high rate. A value of -1 indicates that Blocktimeout has been set 'None' or Storm Detection is 'Normal' status." ::= { atiStkSwPortStormDetectCurrentEntry 3 } atiStkSwPortStormDetectCurrentLowStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), normal (2), detected (3), blocking (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current low rate status of Storm Detection." ::= { atiStkSwPortStormDetectCurrentEntry 4 } atiStkSwPortStormDetectCurrentLowAction OBJECT-TYPE SYNTAX INTEGER { unknown (1), none (2), port-disabled (3), linkdown (4), broadcast-discard (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current low rate action by Storm Detected." ::= { atiStkSwPortStormDetectCurrentEntry 5 } atiStkSwPortStormDetectCurrentLowExpiry OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the remaining time(sec) to back to normal loop status from blocking status of low rate. A value of -1 indicates that Blocktimeout has been set 'None' or Storm Detection is 'Normal' status." ::= { atiStkSwPortStormDetectCurrentEntry 6 } -- atiStkSwPortLoopDetectCurrentTable atiStkSwPortLoopDetectCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwPortLoopDetectCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current Loop Detection informations of a list of physical ports present in the switch." ::= { atiStkSwPortGroup 9 } atiStkSwPortLoopDetectCurrentEntry OBJECT-TYPE SYNTAX AtiStkSwPortLoopDetectCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwPortLoopDetectCurrentTable' that describes the current Loop Detection informations with a physical port present in the switch." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwPortLoopDetectCurrentTable 1 } AtiStkSwPortLoopDetectCurrentEntry ::= SEQUENCE { atiStkSwPortLoopDetectCurrentStatus INTEGER, atiStkSwPortLoopDetectCurrentAction INTEGER, atiStkSwPortLoopDetectCurrentExpiry Integer32, atiStkSwPortLoopDetectCurrentVlanId Integer32, } atiStkSwPortLoopDetectCurrentStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), normal (2), detected (3), blocking (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current loop status of Loop Detection." ::= { atiStkSwPortLoopDetectCurrentEntry 1 } atiStkSwPortLoopDetectCurrentAction OBJECT-TYPE SYNTAX INTEGER { unknown (1), none (2), port-disabled (3), linkdown (4), broadcast-discard (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current loop action by Loop Detected." ::= { atiStkSwPortLoopDetectCurrentEntry 2 } atiStkSwPortLoopDetectCurrentExpiry OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the remaining time(sec) to back to normal status from blocking status. A value of -1 indicates that Blocktimeout has been set 'None' or Loop Detection is 'Normal' status." ::= { atiStkSwPortLoopDetectCurrentEntry 3 } atiStkSwPortLoopDetectCurrentVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the VLAN loop occured." ::= { atiStkSwPortLoopDetectCurrentEntry 4 } -- The atiStkSwVlanGroup -- Defined below atiStkSwVlanConfigTable OBJECT IDENTIFIER ::= { atiStkSwVlanGroup 1 } -- Defined Below atiStkSwPort2VlanTable OBJECT IDENTIFIER ::= { atiStkSwVlanGroup 2 } -- Defined Below atiStkSwMacAddr2VlanTable OBJECT IDENTIFIER ::= { atiStkSwVlanGroup 3 } -- Defined Below atiStkSwGVRPConfig OBJECT IDENTIFIER ::= {atiStkSwVlanGroup 6} -- Defined Below atiStkSwGVRPPortConfigTable OBJECT IDENTIFIER ::= {atiStkSwVlanGroup 7} -- Defined Below atiStkSwGVRPCounters OBJECT IDENTIFIER ::= {atiStkSwVlanGroup 8} -- atiStkSwVlanConfigTable atiStkSwVlanConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of VLANs configured on the switch." ::= { atiStkSwVlanGroup 1 } atiStkSwVlanConfigEntry OBJECT-TYPE SYNTAX AtiStkSwVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwVlanConfigTable' that describes a VLAN configured on the switch." INDEX { atiStkSwVlanId } ::= { atiStkSwVlanConfigTable 1 } AtiStkSwVlanConfigEntry ::= SEQUENCE { atiStkSwVlanId Integer32, atiStkSwVlanName DisplayString, atiStkSwVlanTaggedPortListModule1 DisplayString, atiStkSwVlanUntaggedPortListModule1 DisplayString, atiStkSwVlanActualUntaggedPortListModule1 DisplayString, atiStkSwVlanTaggedPortListModule2 DisplayString, atiStkSwVlanUntaggedPortListModule2 DisplayString, atiStkSwVlanTaggedPortListModule3 DisplayString, atiStkSwVlanUntaggedPortListModule3 DisplayString, atiStkSwVlanTaggedPortListModule4 DisplayString, atiStkSwVlanUntaggedPortListModule4 DisplayString, atiStkSwVlanTaggedPortListModule5 DisplayString, atiStkSwVlanUntaggedPortListModule5 DisplayString, atiStkSwVlanTaggedPortListModule6 DisplayString, atiStkSwVlanUntaggedPortListModule6 DisplayString, atiStkSwVlanTaggedPortListModule7 DisplayString, atiStkSwVlanUntaggedPortListModule7 DisplayString, atiStkSwVlanTaggedPortListModule8 DisplayString, atiStkSwVlanUntaggedPortListModule8 DisplayString, atiStkSwVlanConfigEntryStatus RowStatus } atiStkSwVlanId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN ID of this VLAN as stored in the tag information header in accordance with the 802.1q specifications." ::= { atiStkSwVlanConfigEntry 1 } atiStkSwVlanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the VLAN." ::= { atiStkSwVlanConfigEntry 2 } atiStkSwVlanTaggedPortListModule1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #1) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 3 } atiStkSwVlanUntaggedPortListModule1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #1) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 4 } atiStkSwVlanTaggedPortListModule2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #2) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 5 } atiStkSwVlanUntaggedPortListModule2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #2) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 6 } atiStkSwVlanTaggedPortListModule3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #3) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 7 } atiStkSwVlanUntaggedPortListModule3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #3) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 8 } atiStkSwVlanTaggedPortListModule4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #4) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 9 } atiStkSwVlanUntaggedPortListModule4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #4) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 10 } atiStkSwVlanTaggedPortListModule5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #5) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 11 } atiStkSwVlanUntaggedPortListModule5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #5) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 12 } atiStkSwVlanTaggedPortListModule6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #6) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 13 } atiStkSwVlanUntaggedPortListModule6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #6) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 14 } atiStkSwVlanTaggedPortListModule7 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #7) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 15 } atiStkSwVlanUntaggedPortListModule7 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #7) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 16 } atiStkSwVlanTaggedPortListModule8 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of tagged ports (on module #8) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 17 } atiStkSwVlanUntaggedPortListModule8 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies a list of untagged ports (on module #8) that participate in this VLAN." ::= { atiStkSwVlanConfigEntry 18 } atiStkSwVlanConfigEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The current status of this VLAN entry. Please note the RowStatus implementation details. VLANs can be created with a CreateandWait or CreateAndGo RowStatus. When using CreateAndGo all fields must be valid. VLANs created without a named defined have a NotReady Status. NotReady accepts transitions to NotInService or Active. A NotInService VLAN is not commited to hardware. NotInService accepts transitions to Active or the Destroy action. VLANs in any state other than active is considered non-persistent and is not available after a reset. VLANs in the active state are persistent. An active VLAN cannot accept a transition to NotInService., i.e. from persistent to non-persistent. It may be destroyed." ::= { atiStkSwVlanConfigEntry 19 } atiStkSwVlanActualUntaggedPortListModule1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the list of actual untagged ports that are participating in this VLAN. The untagged port membership can be temporarily changed by 802.1x Dynamic VLAN or Guest VLAN features. The currently effective port membership information can be retrieved from this object. " ::= { atiStkSwVlanConfigEntry 20 } -- atiStkSwPort2VlanTable atiStkSwPort2VlanTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwPort2VlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This tables contains a list of ports in the switch and their associated VLAN configuration information." ::= { atiStkSwVlanGroup 2 } atiStkSwPort2VlanEntry OBJECT-TYPE SYNTAX AtiStkSwPort2VlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwPort2VlanTable' that describes the VLAN information associated with a given module/port." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwPort2VlanTable 1 } AtiStkSwPort2VlanEntry ::= SEQUENCE { atiStkSwPortVlanId Integer32, atiStkSwPortVlanName DisplayString } atiStkSwPortVlanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the VLAN to which this port belongs." ::= { atiStkSwPort2VlanEntry 1 } atiStkSwPortVlanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the VLAN to which this port belongs." ::= { atiStkSwPort2VlanEntry 2 } -- atiStkSwMacAddr2VlanTable atiStkSwMacAddr2VlanTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwMacAddr2VlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of MAC addresses (in the forwarding table of the switch) and the associated VLAN to which each MAC address belongs." ::= { atiStkSwVlanGroup 3 } atiStkSwMacAddr2VlanEntry OBJECT-TYPE SYNTAX AtiStkSwMacAddr2VlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwMacAddr2VlanTable' that associates a MAC address (in the forwarding table of the switch) with the VLAN to which the address belongs." INDEX { atiStkSwMacAddress, atiStkSwMacAddrVlanId } ::= { atiStkSwMacAddr2VlanTable 1 } AtiStkSwMacAddr2VlanEntry ::= SEQUENCE { atiStkSwMacAddress MacAddress, atiStkSwMacAddrVlanId Integer32, atiStkSwMacAddrVlanName DisplayString, atiStkSwMacAddrModuleId Integer32, atiStkSwMacAddrPortId Integer32, atiStkSwMacAddrPortList DisplayString } atiStkSwMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "A MAC address from the forwarding table of the switch." ::= { atiStkSwMacAddr2VlanEntry 1 } atiStkSwMacAddrVlanId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the VLAN to which this MAC address belongs." ::= { atiStkSwMacAddr2VlanEntry 2 } atiStkSwMacAddrVlanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the VLAN to which this MAC address belongs." ::= { atiStkSwMacAddr2VlanEntry 3 } atiStkSwMacAddrModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The module ID on which this MAC address entry exists." ::= { atiStkSwMacAddr2VlanEntry 4 } atiStkSwMacAddrPortId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port ID (on the module specified by 'atiStkSwMacAddrModuleId') on which this MAC address entry exists. This will display 0 for a multicast mac address. Please check the PortList for the Multicast details. Note: This will be eventually deprected approximately Dec'2004." ::= { atiStkSwMacAddr2VlanEntry 5 } atiStkSwMacAddrPortList OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The port List (on the module specified by 'atiStkSwMacAddrModuleId') on which this MAC address entry exists. This is shown as U: Untagged Ports T: Tagged Ports." ::= { atiStkSwMacAddr2VlanEntry 6 } -- Objects to control VLAN mode (user-configured vs pre-configured) atiStkSwVlanMode OBJECT-TYPE SYNTAX INTEGER { user-configured (1), multiple (2), multiple-802-1Q (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the current VLAN mode. Setting this object to 'user-configured (1)' allows the manager to create, delete and modify VLANs using atiStkSwVlanConfigTable'. Setting this object to 'multiple (2)' or 'multiple-802-1Q (3)'will result in the creation of predefined VLANs. Setting these values requires that the object 'atiStkSwVlanUplinkVlanPort' also be set in the same SET request. Note that SET operations on any object under 'atiStkSwVlanConfigTable' are not allowed in these two modes." ::= { atiStkSwVlanGroup 4 } atiStkSwVlanUplinkVlanPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the Uplink VLAN Port ID used while creating pre-configured VLANs. This object can be set to any valid Port ID present on the switch. Note that a SET operation on the object 'atiStkSwVlanMode' to the value 'multiple (2)' or 'multiple-802-1Q (3)' should always be accompanied by a SET operation on this object in the same SET request. By default this object is set to 0 when 'atiStkSwVlanMode' is set to 'user-configured (1)'." ::= { atiStkSwVlanGroup 5 } atiStkSwGVRPConfig OBJECT IDENTIFIER ::= {atiStkSwVlanGroup 6} -- The atiStkSwGVRPConfig atiStkSwGVRPStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabled/Disabled GVRP on a switch basis." ::= { atiStkSwGVRPConfig 1 } atiStkSwGVRPGIPStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabled/Disabled GARP Information Propagation (GIP) on a switch basis." ::= { atiStkSwGVRPConfig 2 } atiStkSwGVRPJoinTimer OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Join Timer in centi seconds, (1/100th of seconds), The default is 20 centi seconds." ::= { atiStkSwGVRPConfig 3 } atiStkSwGVRPLeaveTimer OBJECT-TYPE SYNTAX Integer32 (30..180) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Leave Timer in centi seconds, (1/100th of seconds), The default is 60 centi seconds." ::= { atiStkSwGVRPConfig 4 } atiStkSwGVRPLeaveAllTimer OBJECT-TYPE SYNTAX Integer32 (500..3000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the Leave All Timer in centi seconds, (1/100th of seconds), The default is 1000 centi seconds." ::= { atiStkSwGVRPConfig 5 } -- The atiStkSwGVRPPortConfigTable atiStkSwGVRPPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwGVRPPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is configuring the GVRP Vlan base on each port." ::= { atiStkSwVlanGroup 7 } atiStkSwGVRPPortConfigEntry OBJECT-TYPE SYNTAX AtiStkSwGVRPPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwGVRPPortConfigTable'." INDEX { atiStkSwGVRPPortConfigModuleId, atiStkSwGVRPPortConfigPortId } ::= { atiStkSwGVRPPortConfigTable 1 } AtiStkSwGVRPPortConfigEntry::= SEQUENCE { atiStkSwGVRPPortConfigModuleId Integer32, atiStkSwGVRPPortConfigPortId Integer32, atiStkSwGVRPPortConfigStatus INTEGER } atiStkSwGVRPPortConfigModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "An ID that indicate which module it refer to for stacking." ::= { atiStkSwGVRPPortConfigEntry 1 } atiStkSwGVRPPortConfigPortId OBJECT-TYPE SYNTAX Integer32 (1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "Port Index." ::= { atiStkSwGVRPPortConfigEntry 2 } atiStkSwGVRPPortConfigStatus OBJECT-TYPE SYNTAX INTEGER { none (1), normal (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port Status for GVRP Vlan either Normal or Mode can be set." ::= { atiStkSwGVRPPortConfigEntry 3 } -------------- atiStkSwGVRPCountersTable ---------------------------- atiStkSwGVRPCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwGVRPCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is configuring the GVRP Vlan base on each port." ::= { atiStkSwVlanGroup 8 } atiStkSwGVRPCountersEntry OBJECT-TYPE SYNTAX AtiStkSwGVRPCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwGVRPCountersTable'." INDEX { atiStkSwGVRPCountersModuleId } ::= { atiStkSwGVRPCountersTable 1 } AtiStkSwGVRPCountersEntry::= SEQUENCE { atiStkSwGVRPCountersModuleId Integer32, atiStkSwGVRPCountersGARPRxPkt Counter32, atiStkSwGVRPCountersInvalidGARPRxPkt Counter32, atiStkSwGVRPCountersGARPTxPkt Counter32, atiStkSwGVRPCountersGARPTxDisabled Counter32, atiStkSwGVRPCountersPortNotSending Counter32, atiStkSwGVRPCountersGARPDisabled Counter32, atiStkSwGVRPCountersPortNotListening Counter32, atiStkSwGVRPCountersInvalidPort Counter32, atiStkSwGVRPCountersInvalidProtocol Counter32, atiStkSwGVRPCountersInvalidFormat Counter32, atiStkSwGVRPCountersDatabaseFull Counter32, atiStkSwGVRPCountersRxMsgLeaveAll Counter32, atiStkSwGVRPCountersRxMsgJoinEmpty Counter32, atiStkSwGVRPCountersRxMsgJoinIn Counter32, atiStkSwGVRPCountersRxMsgLeaveEmpty Counter32, atiStkSwGVRPCountersRxMsgLeaveIn Counter32, atiStkSwGVRPCountersRxMsgEmpty Counter32, atiStkSwGVRPCountersRxMsgBadMsg Counter32, atiStkSwGVRPCountersRxMsgBadAttribute Counter32, atiStkSwGVRPCountersTxMsgLeaveAll Counter32, atiStkSwGVRPCountersTxMsgJoinEmpty Counter32, atiStkSwGVRPCountersTxMsgJoinIn Counter32, atiStkSwGVRPCountersTxMsgLeaveEmpty Counter32, atiStkSwGVRPCountersTxMsgLeaveIn Counter32, atiStkSwGVRPCountersTxMsgEmpty Counter32 } atiStkSwGVRPCountersModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "An ID that indicate which module it refer to for stacking." ::= { atiStkSwGVRPCountersEntry 1 } atiStkSwGVRPCountersGARPRxPkt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 2 } atiStkSwGVRPCountersInvalidGARPRxPkt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 3 } atiStkSwGVRPCountersGARPTxPkt OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 4 } atiStkSwGVRPCountersGARPTxDisabled OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 5 } atiStkSwGVRPCountersPortNotSending OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 6 } atiStkSwGVRPCountersGARPDisabled OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 7 } atiStkSwGVRPCountersPortNotListening OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 8 } atiStkSwGVRPCountersInvalidPort OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 9 } atiStkSwGVRPCountersInvalidProtocol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 10 } atiStkSwGVRPCountersInvalidFormat OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 11 } atiStkSwGVRPCountersDatabaseFull OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 12 } atiStkSwGVRPCountersRxMsgLeaveAll OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 13 } atiStkSwGVRPCountersRxMsgJoinEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 14 } atiStkSwGVRPCountersRxMsgJoinIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 15 } atiStkSwGVRPCountersRxMsgLeaveEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 16 } atiStkSwGVRPCountersRxMsgLeaveIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 17 } atiStkSwGVRPCountersRxMsgEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 18 } atiStkSwGVRPCountersRxMsgBadMsg OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 19 } atiStkSwGVRPCountersRxMsgBadAttribute OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 20 } atiStkSwGVRPCountersTxMsgLeaveAll OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 21 } atiStkSwGVRPCountersTxMsgJoinEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 22 } atiStkSwGVRPCountersTxMsgJoinIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 23 } atiStkSwGVRPCountersTxMsgLeaveEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 24 } atiStkSwGVRPCountersTxMsgLeaveIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 25 } atiStkSwGVRPCountersTxMsgEmpty OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwGVRPCountersEntry 26 } -- The atiStkSwMacAddrGroup -- Defined below atiStkSwStaticMacAddrTable OBJECT IDENTIFIER ::= { atiStkSwMacAddrGroup 1 } -- atiStkSwStaticMacAddrTable atiStkSwStaticMacAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwStaticMacAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of static MAC address configured on the switch." ::= { atiStkSwMacAddrGroup 1 } atiStkSwStaticMacAddrEntry OBJECT-TYPE SYNTAX AtiStkSwStaticMacAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is an entry in 'atiStkSwStaticMacAddrTable' that describes a static MAC address configured on a given module and port." INDEX { atiStkSwStaticMacAddress, atiStkSwStaticMacAddrVlanId } ::= { atiStkSwStaticMacAddrTable 1 } AtiStkSwStaticMacAddrEntry ::= SEQUENCE { atiStkSwStaticMacAddress MacAddress, atiStkSwStaticMacAddrVlanId Integer32, atiStkSwStaticMacAddrModuleId Integer32, atiStkSwStaticMacAddrPortId Integer32, atiStkSwStaticMacAddrPortList DisplayString, atiStkSwStaticMacAddrEntryStatus RowStatus } atiStkSwStaticMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the static MAC address of this entry." ::= { atiStkSwStaticMacAddrEntry 1 } atiStkSwStaticMacAddrVlanId OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the VLAN on which this static MAC address entry is configured." ::= { atiStkSwStaticMacAddrEntry 2 } atiStkSwStaticMacAddrModuleId OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The module ID on which this static MAC address entry is configured." ::= { atiStkSwStaticMacAddrEntry 3 } atiStkSwStaticMacAddrPortId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port ID (on the module specified by 'atiStkSwStaticMacAddrModuleId') on which this static MAC address entry is configured. Note: a) When defining a list this value must be 0. b) This is on track to be deprecated approx. Dec'2004." ::= { atiStkSwStaticMacAddrEntry 4 } atiStkSwStaticMacAddrPortList OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The port list (on the module specified by 'atiStkSwStaticMacAddrModuleId') on which this static MAC address entry is configured. This can be a single port for a unicast address or multiple ports for a multicast address. Note: a) The display shows the strings as U: Untagged Port List and T: Tagged Port List. However, when creating an entry, the U: and T: must not be defined. They are automatically created as per the VLAN. b) This must not be defined when adding a unicast mac address. Use PortId in that case." ::= { atiStkSwStaticMacAddrEntry 5 } atiStkSwStaticMacAddrEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The current status of this static MAC address entry." ::= { atiStkSwStaticMacAddrEntry 6 } -- The atiStkSwEthStatsGroup -- Defined below atiStkSwEthModuleMonTable OBJECT IDENTIFIER ::= { atiStkSwEthStatsGroup 1 } -- Defined below atiStkSwEthModuleErrTable OBJECT IDENTIFIER ::= { atiStkSwEthStatsGroup 2 } -- Defined below atiStkSwEthPortMonTable OBJECT IDENTIFIER ::= { atiStkSwEthStatsGroup 3 } -- Defined below atiStkSwEthPortErrTable OBJECT IDENTIFIER ::= { atiStkSwEthStatsGroup 4 } -- atiStkSwEthModuleMonTable atiStkSwEthModuleMonTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwEthModuleMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules and their associated ethernet statistics (measured on the module as a whole)." ::= { atiStkSwEthStatsGroup 1 } atiStkSwEthModuleMonEntry OBJECT-TYPE SYNTAX AtiStkSwEthModuleMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwEthModuleMonTable' that describes the ethernet statistics measured on a given module as a whole." INDEX { atiStkSwModuleId } ::= { atiStkSwEthModuleMonTable 1 } AtiStkSwEthModuleMonEntry ::= SEQUENCE { atiStkSwEthModuleMonTxGoodFrames Counter64, atiStkSwEthModuleMonRxGoodFrames Counter64, atiStkSwEthModuleMonTxTotalBytes Counter64, atiStkSwEthModuleMonTxBroadcastFrames Counter64, atiStkSwEthModuleMonTxMulticastFrames Counter64, atiStkSwEthModuleMonRxOverrunFrames Counter64 } atiStkSwEthModuleMonTxGoodFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good frames transmitted by this module." ::= { atiStkSwEthModuleMonEntry 1 } atiStkSwEthModuleMonRxGoodFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good frames received by this module." ::= { atiStkSwEthModuleMonEntry 2 } atiStkSwEthModuleMonTxTotalBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes transmitted by this module." ::= { atiStkSwEthModuleMonEntry 3 } atiStkSwEthModuleMonTxBroadcastFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of broadcast frames transmitted from this module." ::= { atiStkSwEthModuleMonEntry 4 } atiStkSwEthModuleMonTxMulticastFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of multicast frames transmitted from this module." ::= { atiStkSwEthModuleMonEntry 5 } atiStkSwEthModuleMonRxOverrunFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of oversized frames received on this module." ::= { atiStkSwEthModuleMonEntry 6 } -- atiStkSwEthModuleErrTable atiStkSwEthModuleErrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwEthModuleErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules and their associated ethernet error statistics (measured on the module as a whole)." ::= { atiStkSwEthStatsGroup 2 } atiStkSwEthModuleErrEntry OBJECT-TYPE SYNTAX AtiStkSwEthModuleErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwEthModuleErrTable' that describes the ethernet error statistics measured on a given module as a whole." INDEX { atiStkSwModuleId } ::= { atiStkSwEthModuleErrTable 1 } AtiStkSwEthModuleErrEntry ::= SEQUENCE { atiStkSwEthModuleErrRxCRC Counter64, atiStkSwEthModuleErrRxBadFrames Counter64, atiStkSwEthModuleErrCollisions Counter64 } atiStkSwEthModuleErrRxCRC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of CRC errors on packets received on this module." ::= { atiStkSwEthModuleErrEntry 1 } atiStkSwEthModuleErrRxBadFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bad frames received on this module." ::= { atiStkSwEthModuleErrEntry 2 } atiStkSwEthModuleErrCollisions OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times a collision was detected on this module." ::= { atiStkSwEthModuleErrEntry 3 } -- atiStkSwEthPortMonTable atiStkSwEthPortMonTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwEthPortMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of ports and their associated ethernet statistics." ::= { atiStkSwEthStatsGroup 3 } atiStkSwEthPortMonEntry OBJECT-TYPE SYNTAX AtiStkSwEthPortMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwEthPortMonTable' that describes the ethernet statistics measured on a given module/port." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwEthPortMonTable 1 } AtiStkSwEthPortMonEntry ::= SEQUENCE { atiStkSwEthPortMonTxGoodFrames Counter64, atiStkSwEthPortMonRxGoodFrames Counter64, atiStkSwEthPortMonTxTotalBytes Counter64, atiStkSwEthPortMonTxBroadcastFrames Counter64, atiStkSwEthPortMonTxMulticastFrames Counter64, atiStkSwEthPortMonRxOverrunFrames Counter64 } atiStkSwEthPortMonTxGoodFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good frames transmitted by this port." ::= { atiStkSwEthPortMonEntry 1 } atiStkSwEthPortMonRxGoodFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good frames received by this port." ::= { atiStkSwEthPortMonEntry 2 } atiStkSwEthPortMonTxTotalBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes transmitted by this port." ::= { atiStkSwEthPortMonEntry 3 } atiStkSwEthPortMonTxBroadcastFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of broadcast frames transmitted from this port." ::= { atiStkSwEthPortMonEntry 4 } atiStkSwEthPortMonTxMulticastFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of broadcast frames transmitted from this port." ::= { atiStkSwEthPortMonEntry 5 } atiStkSwEthPortMonRxOverrunFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of oversized frames received on this port." ::= { atiStkSwEthPortMonEntry 6 } -- atiStkSwEthPortErrTable atiStkSwEthPortErrTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwEthPortErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of ports and their associated ethernet error statistics." ::= { atiStkSwEthStatsGroup 4 } atiStkSwEthPortErrEntry OBJECT-TYPE SYNTAX AtiStkSwEthPortErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwEthPortErrTable' that describes the ethernet error statistics measured on a given module/port." INDEX { atiStkSwModuleId, atiStkSwPortId } ::= { atiStkSwEthPortErrTable 1 } AtiStkSwEthPortErrEntry ::= SEQUENCE { atiStkSwEthPortErrRxBadFrames Counter64, atiStkSwEthPortErrCollisions Counter64 } atiStkSwEthPortErrRxBadFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bad frames received on this port." ::= { atiStkSwEthPortErrEntry 1 } atiStkSwEthPortErrCollisions OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times a collision was detected on this port." ::= { atiStkSwEthPortErrEntry 2 } -- The atiStkSwTrapsGroup atiStkSwFanStopTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId } STATUS current DESCRIPTION "This trap is sent out when an error in the fan operation is detected in a module." ::= { atiStkSwTrapsGroup 1 } atiStkSwTemperatureAbnormalTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId } STATUS obsolete DESCRIPTION "This trap is sent out when the temperature of a module becomes abnormal." ::= { atiStkSwTrapsGroup 2 } atiStkSwIntrusionDetectionTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId , atiStkSwIntruderAttackVlanId, atiStkSwIntruderAttackMacAddr } STATUS current DESCRIPTION "This trap is sent out when an intrusion is detected on a port in the switch and the port security has been configured to send traps. It includes the mac address and vlan." ::= { atiStkSwTrapsGroup 3 } atiStkSwDOSTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortDOSAttackType } STATUS current DESCRIPTION "This trap is sent out when DOS (Denial of Service) attack is detected on a port in the switch and the port security has been configured to send traps. This trap is not applicable to 8300 series products." ::= { atiStkSwTrapsGroup 4 } atiStkSwSTPPortStateChangeTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId} STATUS current DESCRIPTION "This trap is sent out when STP port state changes due to RSTP/MSTP topology changes in the switch. This trap is not applicable to 8300 series products." ::= { atiStkSwTrapsGroup 5 } atiStkSwSTPTrunkStateChangeTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId} STATUS current DESCRIPTION "This trap is sent out when STP trunk state changes due to RSTP/MSTP topology changes in the switch. This trap is not applicable to 8300 series products." ::= { atiStkSwTrapsGroup 6 } atiStkSwSysRPSStateChangedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId, atiStkSwSysRPSPresent, atiStkSwSysRPSState , atiStkSwSysDCState } STATUS current DESCRIPTION "This trap is sent out when the RPS(redundant Power Supply) changes state in the switch. Please read the description of the notification objects and their states 'AtiStkSwSysProductInfoEntry' above. This trap is not applicable to 8300 series products." ::= { atiStkSwTrapsGroup 7 } atiStkSwTrapVarMgmtType OBJECT-TYPE SYNTAX INTEGER { notrap(1), ssh (2), telnet (3), web (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of management interface that was last disabled due to continuos invalid logins. This variable is a placeholder for the object sent in the atiStkSwMgmtDisabledTrap, but can be read independently if required. It will hold the value of the latest trap. A value of 'notrap' indicates that no trap has occured of this type from the last bootup time." ::= { atiStkSwTrapsGroup 8 } atiStkSwTrapVarMgmtIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the management station that had continuos invalid logins. This variable is a placeholder for the object sent in the atiStkSwMgmtDisabledTrap, but can be read independently if required. It will hold the value of the latest trap. A value of 0.0.0.0 indicates that no trap has occured of this type from the last bootup time." ::= { atiStkSwTrapsGroup 9 } atiStkSwMgmtDisabledTrap NOTIFICATION-TYPE OBJECTS {atiStkSwTrapVarMgmtType, atiStkSwTrapVarMgmtIpAddr} STATUS current DESCRIPTION "This trap is sent out when a management interface is disabled due to continuos invalid logins. This trap is not applicable to 8300 series products." ::= { atiStkSwTrapsGroup 15 } atiStkSwTemperatureLimitTrap NOTIFICATION-TYPE OBJECTS {atiStkSwSysModuleId, atiStkSwSysTemperatureLimitValue} STATUS current DESCRIPTION "This trap is send when the system temperature crosses threshold values defined for different temperature levels, e.g. high (warning) temperature, critical (error) temperature. Also the threshold limit may be different depends on the model type." ::= { atiStkSwTrapsGroup 16 } atiStkSwFanOkTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId } STATUS current DESCRIPTION "This trap is sent out when a fan become running Ok." ::= { atiStkSwTrapsGroup 17 } atiStkSwTemperatureNormalTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysModuleId } STATUS current DESCRIPTION "This trap is sent out when it is generated when system temperature become normal." ::= { atiStkSwTrapsGroup 18 } atiStkSwHighRateStormDetectedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function detects a received packets rate is over the configured high rate threshold." ::= { atiStkSwTrapsGroup 19 } atiStkSwWarningHighRateStormBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortStormDetectCurrentHighAction } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function blocks a port with over a received packets high rate threshold." ::= { atiStkSwTrapsGroup 20 } atiStkSwRecoverHighRateStormBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function gets a blocked port back to normal." ::= { atiStkSwTrapsGroup 21 } atiStkSwLowRateStormDetectedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function detects a received packets rate is over the configured row rate threshold." ::= { atiStkSwTrapsGroup 22 } atiStkSwWarningLowRateStormBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortStormDetectCurrentLowAction } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function blocks a port with over a received packets low rate threshold." ::= { atiStkSwTrapsGroup 23 } atiStkSwRecoverLowRateStormBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when Storm Detection function gets a blocked port back to normal." ::= { atiStkSwTrapsGroup 24 } atiStkSwStackTopologyChangeTrap NOTIFICATION-TYPE OBJECTS { atiStkSwSysNumOfModuleInStack} STATUS current DESCRIPTION "This trap is sent out when there is a topology change in the stack. Either one or more stack member is added or deleted." ::= { atiStkSwTrapsGroup 25 } atiStkSwBPDUGuardIsTriggeredTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when a BPDU guard detects a spoofed BPDU entering the STP system thru the edge port. The BPDU guard will disable the port and notify the system administrator." ::= { atiStkSwTrapsGroup 26 } atiStkSwLoopDetectedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortLoopDetectCurrentVlanId } STATUS current DESCRIPTION "This trap is sent out when the switch detects a loop by receivig LDF packet." ::= { atiStkSwTrapsGroup 27 } atiStkSwWarningLoopBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId, atiStkSwPortLoopDetectCurrentAction } STATUS current DESCRIPTION "This trap is sent out when Loop Detection function blocks a port." ::= { atiStkSwTrapsGroup 28 } atiStkSwRecoverLoopBlockedTrap NOTIFICATION-TYPE OBJECTS { atiStkSwModuleId, atiStkSwPortId } STATUS current DESCRIPTION "This trap is sent out when Loop Detection function gets a blocked port back to normal." ::= { atiStkSwTrapsGroup 29 } -- The atiStkSwQoSGroup -- This group is not applicable to 8300 series products. atiStkSwQoSGroupNumberOfQueues OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives a count of the CoS Queues supported by the chipset. This object is not applicable to 8300 series products." ::= { atiStkSwQoSGroup 1 } atiStkSwQoSGroupSchedulingMode OBJECT-TYPE SYNTAX INTEGER { strict-priority (1), weighted-round-robin (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows to configure QOS scheduling mode. This object is not applicable to 8300 series products." ::= { atiStkSwQoSGroup 2 } -- The atiStkSwQoSGroupCoSToQueueTable atiStkSwQoSGroupCoSToQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQoSGroupCoSToQueueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table object allows to configure queue for each CoS (Class fo Service) priority. This table object is not applicable to 8300 series products." ::= { atiStkSwQoSGroup 3 } atiStkSwQoSGroupCoSToQueueEntry OBJECT-TYPE SYNTAX AtiStkSwQoSGroupCoSToQueueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQoSGroupCoSToQueueTable' that describes the mapping of CoS priorities to corresponding Cos Queues." INDEX { atiStkSwQoSGroupCoSPriority } ::= { atiStkSwQoSGroupCoSToQueueTable 1 } AtiStkSwQoSGroupCoSToQueueEntry ::= SEQUENCE { atiStkSwQoSGroupCoSPriority INTEGER, atiStkSwQoSGroupCoSQueue INTEGER } atiStkSwQoSGroupCoSPriority OBJECT-TYPE SYNTAX INTEGER { cos-priority-0 (1), cos-priority-1 (2), cos-priority-2 (3), cos-priority-3 (4), cos-priority-4 (5), cos-priority-5 (6), cos-priority-6 (7), cos-priority-7 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the CoS priority." ::= { atiStkSwQoSGroupCoSToQueueEntry 1 } atiStkSwQoSGroupCoSQueue OBJECT-TYPE SYNTAX INTEGER { egress-queue-0 (1), egress-queue-1 (2), egress-queue-2 (3), egress-queue-3 (4), egress-queue-4 (5), egress-queue-5 (6), egress-queue-6 (7), egress-queue-7 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the queue for each CoS priority. Please note that the 94xx supports 8 levels, however, the 85xx supports 4 levels." ::= { atiStkSwQoSGroupCoSToQueueEntry 2 } -- The atiStkSwQoSGroupQueueToWeightTable atiStkSwQoSGroupQueueToWeightTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQoSGroupQueueToWeightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object allows to configure weight for each CoS (Class fo Service) queue . This object table is not applicable to 8300 series products." ::= { atiStkSwQoSGroup 4 } atiStkSwQoSGroupQueueToWeightEntry OBJECT-TYPE SYNTAX AtiStkSwQoSGroupQueueToWeightEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQoSGroupQueueToWeightTable' that describes the mapping of CoS queues to corresponding weights." INDEX { atiStkSwQoSGroupQueue } ::= { atiStkSwQoSGroupQueueToWeightTable 1 } AtiStkSwQoSGroupQueueToWeightEntry ::= SEQUENCE { atiStkSwQoSGroupQueue INTEGER, atiStkSwQoSGroupQueueWeight INTEGER } atiStkSwQoSGroupQueue OBJECT-TYPE SYNTAX INTEGER { egress-queue-0 (1), egress-queue-1 (2), egress-queue-2 (3), egress-queue-3 (4), egress-queue-4 (5), egress-queue-5 (6), egress-queue-6 (7), egress-queue-7 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the queue. Please note that the 94xx supports 8 levels, however, the 85xx supports 4 levels." ::= { atiStkSwQoSGroupQueueToWeightEntry 1 } atiStkSwQoSGroupQueueWeight OBJECT-TYPE SYNTAX INTEGER(0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the queue weight for each queue." ::= { atiStkSwQoSGroupQueueToWeightEntry 2 } -- atiStkSwQosFlowGrpTable -- atiStkSwQosFlowGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQosFlowGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules present in the switch stack and their associated hardware information." ::= { atiStkSwQoSGroup 5 } atiStkSwQosFlowGrpEntry OBJECT-TYPE SYNTAX AtiStkSwQosFlowGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQosFlowGrpTable' that describes the hardware informaton for a module present in the switch stack." INDEX { atiStkSwQosFlowGrpModuleId, atiStkSwQosFlowGrpId } ::= { atiStkSwQosFlowGrpTable 1 } AtiStkSwQosFlowGrpEntry ::= SEQUENCE { atiStkSwQosFlowGrpModuleId Integer32, atiStkSwQosFlowGrpId Integer32, atiStkSwQosFlowGrpDescription DisplayString, atiStkSwQosFlowGrpDSCPValue DisplayString, atiStkSwQosFlowGrpPriority DisplayString, atiStkSwQosFlowGrpRemarkPriority INTEGER, atiStkSwQosFlowGrpTos DisplayString, atiStkSwQosFlowGrpTosToPriority INTEGER, atiStkSwQosFlowGrpPriorityToTos INTEGER, atiStkSwQosFlowGrpClassifierList DisplayString, atiStkSwQosFlowGrpRowStatus RowStatus } atiStkSwQosFlowGrpModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that corresponds to which module the data is retrieved with stacking capability." ::= { atiStkSwQosFlowGrpEntry 1 } atiStkSwQosFlowGrpId OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that corresponds to specific Flow Group base on Id within Flow Group list." ::= { atiStkSwQosFlowGrpEntry 2 } atiStkSwQosFlowGrpDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The description of a specific Flow Group." ::= { atiStkSwQosFlowGrpEntry 3 } atiStkSwQosFlowGrpDSCPValue OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 4 } atiStkSwQosFlowGrpPriority OBJECT-TYPE SYNTAX DisplayString (SIZE(0..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 5 } atiStkSwQosFlowGrpRemarkPriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 6 } atiStkSwQosFlowGrpTos OBJECT-TYPE SYNTAX DisplayString (SIZE(0..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 7 } atiStkSwQosFlowGrpTosToPriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 8 } atiStkSwQosFlowGrpPriorityToTos OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 9 } atiStkSwQosFlowGrpClassifierList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 10 } atiStkSwQosFlowGrpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { atiStkSwQosFlowGrpEntry 11 } -- atiStkSwQosTrafficClassTable atiStkSwQosTrafficClassTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQosTrafficClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules present in the switch stack and their associated hardware information." ::= { atiStkSwQoSGroup 6 } atiStkSwQosTrafficClassEntry OBJECT-TYPE SYNTAX AtiStkSwQosTrafficClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQosTrafficClassTable' that describes the hardware informaton for a module present in the switch stack." INDEX { atiStkSwQosTrafficClassModuleId, atiStkSwQosTrafficClassId } ::= { atiStkSwQosTrafficClassTable 1 } AtiStkSwQosTrafficClassEntry ::= SEQUENCE { atiStkSwQosTrafficClassModuleId Integer32, atiStkSwQosTrafficClassId Integer32, atiStkSwQosTrafficClassDescription DisplayString, atiStkSwQosTrafficClassExceedAction INTEGER, atiStkSwQosTrafficClassExceedRemarkValue Integer32, atiStkSwQosTrafficClassDSCPValue DisplayString, atiStkSwQosTrafficClassMaxBandwidth DisplayString, atiStkSwQosTrafficClassBurstSize DisplayString, atiStkSwQosTrafficClassPriority DisplayString, atiStkSwQosTrafficClassRemarkPriority INTEGER, atiStkSwQosTrafficClassToS DisplayString, atiStkSwQosTrafficClassMoveToSToPriority INTEGER, atiStkSwQosTrafficClassMovePriorityToToS INTEGER, atiStkSwQosTrafficClassFlowGroupList DisplayString, atiStkSwQosTrafficClassRowStatus RowStatus } atiStkSwQosTrafficClassModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 1 } atiStkSwQosTrafficClassId OBJECT-TYPE SYNTAX Integer32 (0..511) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 2 } atiStkSwQosTrafficClassDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 3 } atiStkSwQosTrafficClassExceedAction OBJECT-TYPE SYNTAX INTEGER { drop (1), remark (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 4 } atiStkSwQosTrafficClassExceedRemarkValue OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 5 } atiStkSwQosTrafficClassDSCPValue OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 6 } atiStkSwQosTrafficClassMaxBandwidth OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 7 } atiStkSwQosTrafficClassBurstSize OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 8 } atiStkSwQosTrafficClassPriority OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 9 } atiStkSwQosTrafficClassRemarkPriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 10 } atiStkSwQosTrafficClassToS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 11 } atiStkSwQosTrafficClassMoveToSToPriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 12 } atiStkSwQosTrafficClassMovePriorityToToS OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 13 } atiStkSwQosTrafficClassFlowGroupList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 14 } atiStkSwQosTrafficClassRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { atiStkSwQosTrafficClassEntry 15 } -- atiStkSwQosPolicyTable atiStkSwQosPolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQosPolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of modules present in the switch stack and their associated hardware information." ::= { atiStkSwQoSGroup 7 } atiStkSwQosPolicyEntry OBJECT-TYPE SYNTAX AtiStkSwQosPolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQosPolicyTable' that describes the hardware informaton for a module present in the switch stack." INDEX { atiStkSwQosPolicyModuleId, atiStkSwQosPolicyId } ::= { atiStkSwQosPolicyTable 1 } AtiStkSwQosPolicyEntry ::= SEQUENCE { atiStkSwQosPolicyModuleId Integer32, atiStkSwQosPolicyId Integer32, atiStkSwQosPolicyDescription DisplayString, atiStkSwQosPolicyRemarkDSCP INTEGER, atiStkSwQosPolicyDSCPValue DisplayString, atiStkSwQosPolicyToS DisplayString, atiStkSwQosPolicyMoveToSToPriority INTEGER, atiStkSwQosPolicyMovePriorityToToS INTEGER, atiStkSwQosPolicySendToMirrorPort INTEGER, atiStkSwQosPolicyTrafficClassList DisplayString, atiStkSwQosPolicyRedirectPort DisplayString, atiStkSwQosPolicyIngressPortList DisplayString, atiStkSwQosPolicyEgressPortList DisplayString, atiStkSwQosPolicyRowStatus RowStatus } atiStkSwQosPolicyModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 1 } atiStkSwQosPolicyId OBJECT-TYPE SYNTAX Integer32 (0..511) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 2 } atiStkSwQosPolicyDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 3 } atiStkSwQosPolicyRemarkDSCP OBJECT-TYPE SYNTAX INTEGER { all (1), none (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 4 } atiStkSwQosPolicyDSCPValue OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 5 } atiStkSwQosPolicyToS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 6 } atiStkSwQosPolicyMoveToSToPriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 7 } atiStkSwQosPolicyMovePriorityToToS OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 8 } atiStkSwQosPolicySendToMirrorPort OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 9 } atiStkSwQosPolicyTrafficClassList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 10 } atiStkSwQosPolicyRedirectPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 11 } atiStkSwQosPolicyIngressPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 12 } atiStkSwQosPolicyEgressPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 13 } atiStkSwQosPolicyRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { atiStkSwQosPolicyEntry 14 } -- atiStkSwQosGroupPortCosPriorityTable atiStkSwQoSGroupPortCoSPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwQoSGroupPortCoSPriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table object allows to configure port priority for each CoS (Class of Service) priority. This table object is not applicable to 8300 series products." ::= { atiStkSwQoSGroup 8 } atiStkSwQoSGroupPortCoSPriorityEntry OBJECT-TYPE SYNTAX AtiStkSwQoSGroupPortCoSPriorityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwQoSGroupPortCoSPriorityTable' it defines the CoS priority for each port, and the priority defined for a port should override priority already in the priority tagged packet received by the switch." INDEX { atiStkSwQoSGroupPortCoSPriorityModuleId, atiStkSwQoSGroupPortCoSPriorityPortId } ::= { atiStkSwQoSGroupPortCoSPriorityTable 1 } AtiStkSwQoSGroupPortCoSPriorityEntry ::= SEQUENCE { atiStkSwQoSGroupPortCoSPriorityModuleId Integer32, atiStkSwQoSGroupPortCoSPriorityPortId Integer32, atiStkSwQoSGroupPortCoSPriorityPriority Integer32, atiStkSwQoSGroupPortCoSPriorityOverridePriority INTEGER } atiStkSwQoSGroupPortCoSPriorityModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Module Id of the table." ::= { atiStkSwQoSGroupPortCoSPriorityEntry 1 } atiStkSwQoSGroupPortCoSPriorityPortId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the IfIndex of the table." ::= { atiStkSwQoSGroupPortCoSPriorityEntry 2 } atiStkSwQoSGroupPortCoSPriorityPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the priority for each port CoS priority." ::= { atiStkSwQoSGroupPortCoSPriorityEntry 3 } atiStkSwQoSGroupPortCoSPriorityOverridePriority OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the override priority for each port CoS priority." ::= { atiStkSwQoSGroupPortCoSPriorityEntry 4 } -- atiStkSwStaticTrunkTable atiStkSwStaticTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwStaticTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of static trunk configuration present in the switch stack." ::= { atiStkSwTrunkGroup 1 } atiStkSwStaticTrunkEntry OBJECT-TYPE SYNTAX AtiStkSwStaticTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwStaticTrunkTable' that describes the static trunk informaton for a module present in the switch stack." INDEX { atiStkSwStaticTrunkModuleId, atiStkSwStaticTrunkIndex } ::= { atiStkSwStaticTrunkTable 1 } AtiStkSwStaticTrunkEntry ::= SEQUENCE { atiStkSwStaticTrunkModuleId Integer32, atiStkSwStaticTrunkIndex Integer32, atiStkSwStaticTrunkId Integer32, atiStkSwStaticTrunkName DisplayString, atiStkSwStaticTrunkMethod INTEGER, atiStkSwStaticTrunkPortList DisplayString, atiStkSwStaticTrunkStatus INTEGER, atiStkSwStaticTrunkRowStatus RowStatus } atiStkSwStaticTrunkModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "An identifier for switch stack." ::= { atiStkSwStaticTrunkEntry 1 } atiStkSwStaticTrunkIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index for a trunk entry." ::= { atiStkSwStaticTrunkEntry 2 } atiStkSwStaticTrunkId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An identifier for a trunk." ::= { atiStkSwStaticTrunkEntry 3 } atiStkSwStaticTrunkName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name of a trunk, once the entry has created, it cannot be changed." ::= { atiStkSwStaticTrunkEntry 4 } atiStkSwStaticTrunkMethod OBJECT-TYPE SYNTAX INTEGER { srcIp (1), dstIp (2), src-dstIp (3), srcMac (4), dstMac (5), src-dstMac (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk distribution mode." ::= { atiStkSwStaticTrunkEntry 5 } atiStkSwStaticTrunkPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A list of ports that used as a trunk port." ::= { atiStkSwStaticTrunkEntry 6 } atiStkSwStaticTrunkStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the trunk, either up or down." ::= { atiStkSwStaticTrunkEntry 7 } atiStkSwStaticTrunkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Row Status." ::= { atiStkSwStaticTrunkEntry 8 } -- atiStkSwACLConfigTable atiStkSwACLConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AtiStkSwACLConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a Access Control List (ACL) in the switch and their associated attributes." ::= { atiStkSwACLGroup 1 } atiStkSwACLConfigEntry OBJECT-TYPE SYNTAX AtiStkSwACLConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies an entry in 'atiStkSwACLConfigTable' that describes the ACL in the switch." INDEX { atiStkSwACLModuleId, atiStkSwACLId } ::= { atiStkSwACLConfigTable 1 } AtiStkSwACLConfigEntry ::= SEQUENCE { atiStkSwACLModuleId Integer32, atiStkSwACLId Integer32, atiStkSwACLDescription DisplayString, atiStkSwACLAction INTEGER, atiStkSwACLClassifierList DisplayString, atiStkSwACLPortList DisplayString, atiStkSwACLRowStatus RowStatus } atiStkSwACLModuleId OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ID of a module present in the switch stack." ::= { atiStkSwACLConfigEntry 1 } atiStkSwACLId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the ID of the ACL table." ::= { atiStkSwACLConfigEntry 2 } atiStkSwACLDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "The description of the ACL entry." ::= { atiStkSwACLConfigEntry 3 } atiStkSwACLAction OBJECT-TYPE SYNTAX INTEGER { deny (1), permit (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The action of the ACL entry either deny or permit." ::= { atiStkSwACLConfigEntry 4 } atiStkSwACLClassifierList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The classifier list of the entry." ::= { atiStkSwACLConfigEntry 5 } atiStkSwACLPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The port list of the ACL entry." ::= { atiStkSwACLConfigEntry 6 } atiStkSwACLRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The row status of the table." ::= { atiStkSwACLConfigEntry 7 } END